Cisco Systems 2820, 1900 manual Resolved Caveats in Previous Versions

Page 11

Caveats

Resolved Caveats in Previous Versions

These problems were resolved in version 9.00.05:

CSCds09069

Catalyst 1900 and 2820 switches can now communicate with other management VLANs even if the switch has no ARP entry in its ARP table for a default gateway or does not have a port assigned to a management VLAN.

CSCds60075

The MIB object IfLastChange now reports the correct time when the LinkUp/LinkDown Traps are disabled on the switch.

CSCdt65828

The FDDI DAS module no longer incorrectly appears as an SAS module in a Catalyst 2820 switch.

CSCdr56930

The show cdp neighbor detail command now works correctly on the switch and no longer shows only the IP address of the command switch.

CSCds57774

The switch no longer fails when the HTTP server is enabled and a browser tries to access the URL http://switch-ipaddr/anytext?/.

CSCds77252

Catalyst 1900 and 2820 switches running Enterprise software release 9.00.05 can now answer queries for the MIB object ipAdEntNetMask when you use the snmpget command.

CSCdt33416

SNMP operations with null community strings are no longer allowed.

CSCdv09114

If a switch is installed before the DHCP scope is configured on the DHCP server, or before the DHCP server is online the switch now completes automatic configuration through TFTP.

CSCdv11505

Catalyst 1900 and 2820 switches now respond to ARP requests in a redundant uplink configuration where there are no access ports assigned to the management VLAN.

CSCdv35159

Catalyst 1900 and 2820 switches no longer allow community strings ending with a numeral or an @ symbol.

CSCdu56824

Catalyst 1900 and 2820 switches no longer allow privileged EXEC access with a user EXEC password.

Release Notes for the Catalyst 1900 and Catalyst 2820 Series Switches, Version 9.00.06

 

OL-2901-01

11

 

 

 

Image 11
Contents Contents Supported Browsers Using Previous Releases of the Switch FirmwareFeatures Usage Guidelines Limitation Specific to the Catalyst 2820 SwitchesUsage Guidelines Specific to the Catalyst 1900 Switches LimitationsUsage Guidelines Specific to the Catalyst 2820 Switches Usage Guidelines Open Caveats CaveatsCaveats Caveats Resolved Caveats in Version Resolved Caveats in Previous Versions Caveats Documentation CD-ROM Related DocumentationObtaining Documentation World Wide WebObtaining Technical Assistance Ordering DocumentationDocumentation Feedback Technical Assistance Center Cisco.comCisco TAC Web Site