Cisco Systems CHAS-7K, MAS-7507, MAS-7K, CHAS-7507 manual Interface Processor, SP, and SSP LEDs

Page 31

Verifying the Installation

Interface Processor, SP, and SSP LEDs

The SP or SSP (on the Cisco 7000) and all interface processors contain an enabled LED. When on, this LED indicates that the SP or interface processor is operational and that it is powered up. It does not necessarily mean that the interface ports on the interface processors are functional or enabled. When the boot sequence is complete, all of the enabled LEDs (on the SP and all interface processors) should go on. If any do not go on, one of the following errors is indicated:

The interface processor or SP is not installed correctly (it is not fully seated in the backplane connector).

The SP or interface processor has failed.

System Startup Sequence

By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. The functions of the chassis front panel LEDs are duplicated on the RP (or RSP2) and the power supplies. Because you turn on the system power with the power supply switches, it is easiest to observe the startup behavior from the rear of the chassis.

Most often, problems you encounter while replacing the components in a new chassis will be caused by power supplies or processor modules that are not properly installed and, therefore, are not connected properly inside the chassis. Use the following descriptions of the normal startup sequence to isolate the problem, then use the troubleshooting procedures wherever the system fails to operate as expected.

When you start up the system by turning on the power supply switches (lower power supply first, upper power supply second) you should observe the following:

Step 1 When you turn the lower power supply ON, the power LED on the lower power supply should go on, and the DC fail (or output fail) LED should remain off.

If the power supply switch resists, the power supply is probably not fully inserted into the bay. Turn the power switch OFF (fully counterclockwise to O), pull the power supply out of the bay about two inches, then push the power supply firmly back into the slot. Do not slam the supply into the slot; doing so can damage the connectors on the supply and the backplane. Tighten the captive installation screw before proceeding.

If the power LED goes on, the power source is good, and the power supply is functional.

If the DC fail (or output fail) LED goes on, or if the power LED does not go on, suspect the power supply or the power source. Try to power up the system with the upper power supply if one is present.

Step 2 When you turn the upper power supply ON, the power LED on the upper power supply should go on, and the DC fail (or output fail) LED should remain off.

If the power LED goes on, the power source is good, and the power supply is functional.

If the DC fail (or output fail) LED goes on, or if the power LED does not go on, suspect the power supply or the power source. If the lower power supply is functioning properly, continue monitoring the startup sequence.

If the LEDs on one or both power supplies fail to go on as expected, suspect a power supply or input power failure. Before contacting a service representative, refer to the Cisco 7000 Hardware Installation and Maintenance or Cisco 7507 Hardware Installation and Maintenance publications for power subsystem troubleshooting procedures.

Cisco 7000 and Cisco 7507 Chassis Replacement Instructions 31

Image 31
Contents Cisco 7000 and Cisco Chassis Replacement Instructions Cisco 7000 Chassis Rear View Product OverviewCisco 7507 Chassis Rear View Power Supply Safety Interlocks Cisco 7507 System Backplane Slot Key Guides Prerequisites Safety Guidelines Lifting the Chassis Safely Cable Strain Relief Safety with ElectricityPreventing Electrostatic Discharge Damage List of Parts and ToolsReplacing a Rack-Mounted Chassis Unpacking the ChassisPreparing the Work Area Replacing a Rack-Mounted Chassis Adding a New Chassis to the Rack Replacing the Existing Rack-Mounted Chassis Replacing a Rack-Mounted Chassis Rack Mounting Hardware Replacing a Rack-Mounted Chassis Moving the Processor Modules Moving System ComponentsBottom Ejector Lever and Captive Installation Screw Handling a Processor Module During Installation Moving Power Supplies Handling a Power Supply AC-Input Power Supply Shown DC-Input Power Supply Cable Connections Checking Connections Verifying the InstallationRestarting the System Verifying the Installation LED Descriptions Troubleshooting the InstallationOUT Inputfail Power System Front Panel LEDs Normal Normal Eject Interface Processor, SP, and SSP LEDs Verifying the Installation Verifying the Installation Chassis serial number Slot Circle one RSP2 Power Disconnection Warning Translated Safety WarningsPower Supply Warning Power Supply Disconnection Warning Electric Shock Warning Chassis Lifting Warning DC Power Disconnection Warning Lightning Activity Warning Chassis Warning-Rack-Mounting and Servicing Translated Safety Warnings Ramp Warning DC Power Supply WarningDC Power Supply Wiring Warning DC Power Connection Warning Translated Safety Warnings Cisco Information Online