Cisco Systems 7513 manual Copyright 2004 Cisco Systems, Inc. All rights reserved

Page 1

Upgrading the 1200-Watt, AC-Input

Power Supplies in the Cisco 7513

This document contains instructions for upgrading your existing Cisco 7513, 1200-watt (W), alternating current (AC)–input power supplies, with new AC-input power supplies. (See .) A single power supply is standard equipment for the Cisco 7513. A second, identical power supply, when installed, provides redundant power. In systems with redundant power, the power supplies are load-sharing and fully hot-swappable; you can remove and replace one supply, while the remaining supply immediately ramps up to full power to maintain uninterrupted system operation.

Caution The new and older power supplies must not be used simultaneously in the Cisco 7513. The redundant power, load-sharing feature of the Cisco 7513 requires identical power supplies in each of the two power supply bays. While no physical damage will occur if two different supplies are installed into a Cisco 7513, there is the possibility of erratic system behavior and error messages.

Note If your Cisco 7513 contains older AC-input power supplies, Part Number 34-0049-01, or later, use this document to replace them with new power supplies carrying Part Number 34-0667-01 or later. If you have a Cisco 7513 with one or two of the older AC-input power supplies, you must replace both of them with the new AC-input power supplies. All Cisco 7513 chassis must have the new AC-input power supplies installed in them.

The sections in this document include the following:

Determining the Power Supply Model, page 2

Product Overview, page 3

Installation Safety, ESD Precautions, and Tools Required, page 12

Replacing Older AC-Input Power Supplies, page 14

Checking the New Power Supply Installation, page 18

Related Documentation, page 20

Obtaining Documentation, page 20

Documentation Feedback, page 21

Corporate Headquarters:

Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA

Copyright © 2004 Cisco Systems, Inc. All rights reserved.

Image 1 Contents
Copyright 2004 Cisco Systems, Inc. All rights reserved Label on the New AC-Input Power Supply Right Side View Determining the Power Supply ModelReceptacle Product OverviewCisco 7513 Rear-Panel View with the New Power Supplies Specification Rating Power Supply SpecificationsAC-Input Power Supply LEDs, New Power Supply Power Supply LED IndicationsPower Environmental Monitoring Environmental Monitoring and Reporting FunctionsNormal High Warning High Critical Shutdown Router# show env last Environmental ReportsRouter# show env table Safety Guidelines Installation Safety, ESD Precautions, and Tools RequiredSafety with Electricity Preventing Electrostatic Discharge Damage Tools and Parts RequiredCircuit Protection Requirements Replacing Older AC-Input Power SuppliesOFF position Removing Older Power SuppliesSupporting the Older Power Supply Installing New Power SuppliesSupporting the New Power Suppl Checking the New Power Supply Installation Power Cord Warning Obtaining Documentation Related DocumentationCisco.com Ordering DocumentationDocumentation Feedback Submitting a Service RequestObtaining Technical Assistance Cisco Technical Support WebsiteObtaining Additional Publications and Information Definitions of Service Request SeverityObtaining Additional Publications and Information OL-6324-01