Cabletron Systems KBU64 Rackmount user manual Configuration Using a Manager Card, Xxx

Page 19

KBU64 Rackmount User Manual

4.2 Configuration Using a Manager Card

With the Manager Card pair and all KBU card pairs fitted the first task is to set the individual KBU 64 poll numbers. Once all the units are installed and a suitable terminal connected to the rack manager card command port, the lockout switches should be set to disable access to all the KBU 64s except one (for the sake of convenience it is better to configure the left most KBU 64 first). The individual poll address can then be set by typing the following commands:-

1> SET POLL xxx[CR]

where

xxx

represents the unique address in the range 001 to

999

 

 

Next, the KBU 64 card needs to be set for polled mode by typing

1> SET CONSOLE POLL[CR]

To check that the KBU 64 is responding, type

1> POLL xxx [CR]

where

xxx

represents the address that you have just set

The lockout switch for this KBU 64 should then be set to disable the KBU 64 and the next KBU 64 can be programmed by enabling via the lockout switches etc. etc.

Once all the KBU 64s have been programmed, the lockout switches must be set to enable ALL the KBU 64s.

4–2

80-10100001-09

Image 19
Contents KBU64 Rackmount Publication Notice Proprietary Notice Approval Notice 80-10100001-09 Iii KBU 64 Rackmount Specification Introduction Fivemere KBU 64 Rackmount Specification Rear Interface Cards Front PanelFront and rear Panel Layout Link Settings Command Port KBU 64 Rear Interface Cards 3 V35 Rear Interface Card 4 X21 Rear Interface Card Manager Card Ro n t Rear Panel 80-10100001-09 Manager Card Installation Card InstallationXxx Configuration Using a Manager CardInstallation and Power Supply Requirements 80-10100001-09 Installation and Power Supply Requirements Rack Specifications Environment Additional UK Requirements United Kingdom and Europe80-10100001-09