KBU64 Rackmount User Manual
should be removed and the cable
The wires in the supply cord are coloured in accordance with the following code:-
Green and Yellow Earth
BlueNeutral
BrownLive
As these colours may not correspond with the termination's in the plug being used, it should be connected as follows:-
The green and yellow wire must be connected to the terminal marked with the letter E, or with the earth symbol, or coloured green, or coloured green and yellow.
The blue wire must be connected to the terminal marked with the letter N, or coloured black, or coloured blue.
The brown wire must be connected to the terminal marked with the letter L, or coloured red, or coloured brown.
All data communications links to the frame should be in accordance with the cable specifications given in KBU 64 Standalone Manual
The unit can be connected to supplies of the following voltage ranges:-
a) 97V AC to 132V AC | (110 to 120V Nominal) |
c) 195V AC to 264V AC | (220 to 240V Nominal) |
Supply frequencies, in all cases, can be in the range 47Hz to 63Hz.
The maximum power consumption of the unit is 125 watts. The current requirement for each of the voltage ranges is:-
a)2A max.
b)1A max.
Ideal mains inlet fuse rating:
20mm x 5mm, 1.6AH,250V
|