Cabletron Systems KBU64 Rackmount user manual 80-10100001-09

Page 21

KBU64 Rackmount User Manual

should be removed and the cable re-wired to the correct type of plug. The use of adaptors is not recommended.

The wires in the supply cord are coloured in accordance with the following code:-

Green and Yellow Earth

BlueNeutral

BrownLive

As these colours may not correspond with the termination's in the plug being used, it should be connected as follows:-

The green and yellow wire must be connected to the terminal marked with the letter E, or with the earth symbol, or coloured green, or coloured green and yellow.

The blue wire must be connected to the terminal marked with the letter N, or coloured black, or coloured blue.

The brown wire must be connected to the terminal marked with the letter L, or coloured red, or coloured brown.

All data communications links to the frame should be in accordance with the cable specifications given in KBU 64 Standalone Manual 80-10100000. The rear panel connectors have been fitted with 4-40 screw-locks.

The unit can be connected to supplies of the following voltage ranges:-

a) 97V AC to 132V AC

(110 to 120V Nominal)

c) 195V AC to 264V AC

(220 to 240V Nominal)

Supply frequencies, in all cases, can be in the range 47Hz to 63Hz.

The maximum power consumption of the unit is 125 watts. The current requirement for each of the voltage ranges is:-

a)2A max.

b)1A max.

Ideal mains inlet fuse rating:

20mm x 5mm, 1.6AH,250V Anti-surge (T) type for 220V to 240V ratings.

5–2

80-10100001-09

Image 21
Contents KBU64 Rackmount Publication Notice Proprietary Notice Approval Notice 80-10100001-09 Iii KBU 64 Rackmount Specification Introduction Fivemere KBU 64 Rackmount Specification Rear Interface Cards Front PanelFront and rear Panel Layout Link Settings Command Port KBU 64 Rear Interface Cards 3 V35 Rear Interface Card 4 X21 Rear Interface Card Manager Card Ro n t Rear Panel 80-10100001-09 Manager Card Installation Card InstallationXxx Configuration Using a Manager CardInstallation and Power Supply Requirements 80-10100001-09 Installation and Power Supply Requirements Rack Specifications Environment Additional UK Requirements United Kingdom and Europe80-10100001-09