Avenview C-EDID-RW Hardware Installation, Software Installation, Read the Edid from a Display

Page 7

1.9Hardware Installation

To setup Avenview C-EDID-RW follow these steps for connecting to a device:

1.9.1Read the EDID from a Display

1.Before connecting the Power and other devices to C-EDID-RW, set the DIP switches at the bottom of C-EDID-RW at 1-OFF 2-ON

2.Connect your monitor to the C-EDID-RW and plug in 5V DC Power cord

3.Remove 5V DC power cord when the green LED turns off

4.Connect the C-EDID-RW to your computer by a DVI cable and boot up your computer

1.9.2Recall the default Universal EDID

1.Before connecting the Power and other devices to C-EDID-RW, set the DIP switches at the bottom of C-EDID-RW at 1-ON 2-ON

2.Plug in 5V DC power cord and remove the power when the green LED turns off

3.Connect your monitor to C-EDID-RW

4.Connect the C-EDID-RW to your computer by a DVI cable and boot up your computer

1.9.3Write EDID to Display

1.Before connecting the Power and other devices to C-EDID-RW, set the DIP switches at the bottom of C-EDID-RW at 1-ON 2-OFF

2.Plug in 5V DC power cord

3.Connect your monitor (DVI cable) and computer’s RS232 cable to C-EDID-RW

4.Boot up your computer and install the software

5.Refer to software installation below.

1.10 Software Installation

Before launching the software installation, please make sure:

1.The power supply is well connected

2.DIP switches are at the right position as shown below

www.avenview.com

7

 

 

Image 7
Contents Edid Reader / Writer Table of Contents Safety Instructions Important SafeguardsGetting Started Introduction Package ContentsBefore Installation Regulatory Notices Federal Communications Commission FCCFront Panel Panel DescriptionMode DIP Switch ConfigurationRead the Edid from a Display Hardware InstallationSoftware Installation Recall the default Universal EdidWrite Edid Read EdidDVI Monitor Write SpecificationsDisclaimer