Extron electronic HSA 400, HSA 402 Installation Overview, Preparing the Routing Template

Page 8

Installation

Installation Overview

Install and set up the HSA surface access enclosure as follows:

1If you have an unprepared mounting template, prepare the template. See “Preparing the Routing Template” on the next page.

2If desired, install the optional RJ-45 to RJ-11 conversion kit(s) to replace one or more RJ-45 connectors with RJ-11 connectors. Refer to the RJ-45 to RJ-11 Conversion Kit manual.

3If desired, install the optional flexible conduit kit to replace the removable AC power cord. Refer to the Flexible Conduit Kit manual.

4Cut a hole in the surface where the enclosure will be installed and install the enclosure. The clamshell clamps the enclosure to the table. See “Preparing the Table and Mounting the Enclosure” in this chapter.

5Run all cables necessary to support the AC and RJ-45 connectors and all planned AAP connectors. Leave enough slack in the cables to connect them to the underside of the enclosure or to the rear of the AAPs before the AAPs are installed in the enclosure.

6Turn off all of the equipment to be connected. Ensure that the equipment connected to the RJ-45 connectors and the connections for any AAPs are all turned off and disconnected from the power source.

7If applicable, connect cables to the rear connectors on the AAPs to be installed in the HSA. Install the desired AAPs on the front panel of the enclosure. See “Cabling and Installing the AAPs” in this chapter.

8Connect the power and RJ-45 cables to the underside of the enclosure. See “Cabling the Enclosure” in this chapter.

9Route and secure the AAP cables inside the clamshell. See “Routing the AAP Cables” in this chapter.

10Peel the protective coating from the top surface.

11Connect the power cords and turn on the devices that connect to the surface access enclosure.

Preparing the Routing Template

Extron offers a metal template for each HSA model. Appendix A lists the HSA 400/402 template part numbers. Extron recommends using this template as a guide to cut the hole in the table where the HSA will be installed.

 

The metal routing template is reusable. Do not discard

 

this template when the installation is complete. Save it

 

for installing future HSA enclosures of the same size.

1.

Cut two 1/2" x 4" (approximately 13 mm x 102 mm) strips

 

of soft, finished lumber at least long enough to span the

 

distance between the desired installation location on the

 

table or other mounting surface and the edges of the

 

mounting surface (figure 2-1).

 

 

CAUTION

Do not allow the wood screws to protrude through

 

 

the bottom of the wooden strips. Protruding screws

 

 

will mar the table when the template is used.

 

 

 

Mounting

 

 

 

Surface

 

 

 

Edge

 

 

Minimum

Wood

 

 

4 Screws

Strips

 

 

 

Wood Strip

 

 

 

Height

 

 

 

4" / 10.2 cm

Mounting

 

 

Routing Template

Surface

 

 

 

Edge

 

 

 

Wood Thickness 0.5" / 1.3 cm

Figure 2-1 — Prepared mounting template

These strips raise the routing template above the mounting surface to provide room for the router’s collar, protect the mounting surface, and extend the routing template’s reach so that it can be clamped to the edge of the surface.

2. Using four or more short wood screws, secure the mounting template to the lumber strips.

2-2

HSA 400/402 Series • Installation

HSA 400/402 Series • Installation

2-3

Image 8
Contents HSA 400 & HSA 402 US/Domestic Precautions s Table of Contents Introduction HSA 400/402 Series Surface Access ProductsTable of Contents, cont’d Introduction About the Hideaway Surface Access ProductsFeatures Installation Introduction, cont’dPreparing the Routing Template InstallationInstallation Overview Template when the installation is complete. Save it For installing other HSA products of the same sizeOther installation surface. Mark the location Place the mounting template assembly on the tableInstallation, cont’d Cabling and Installing the AAPsCabling the Enclosure Mounting an AAP device to an HSA 400 US front panelCable access holes Only connectors 1A and 1B are present on the HSAInstallation, cont’d Routing the AAP Cables BezelsMaintenance and Modifications ThreeMaintenance and Modifications Replacing an AAPMaintenance and Modifications, cont’d Replacing the Bezels Removing and Replacing the EnclosureMaintenance and Modifications, cont’d When the HSA 400/402 is upside-down, the latch May be ineffective. If the latch releases, the enclosureWill tip and could damage the flanged edges. Keep a Hand on the enclosure to keep it from tippingAAppendix a Reference InformationSpecifications Reference InformationReplacement Parts and Accessories Interface AccessoriesReference Information, cont’d HSA Part Numbers Included PartsReference Information, cont’d Top Plate Dimensions US ModelReference Information, cont’d 15.05 + 0.083 cmPackaging for Shipment Reference Information,Internationalc t’d ModelAre sharp when the HSA is removed from the table Exercise caution when handling to prevent personalPackaging for Shipment Flanged edges of the top of the surface enclosureFigure B-4 Installing protective strips Packaging for Shipment, cont’dFigure B-6 HSA suspended in the foam Vertical Foams
Related manuals
Manual 28 pages 1.18 Kb

HSA 400 INTERNATIONAL, HSA 402 INTERNATIONAL, HSA 402, HSA 400 specifications

Extron is a well-known company specializing in the design and manufacturing of high-quality AV signal routing, distribution, and control solutions. Among its impressive lineup, the Extron HSA 400 and HSA 402 models, as well as the RGB 580xi AAP, stand out for their exceptional performance and versatility in audio and video integration.

Starting with the HSA 400 and HSA 402, these are high-performance audio switches designed for efficient audio management in professional AV environments. The HSA 400 supports up to four stereo audio input channels, while the HSA 402 expands this capability to two outputs. Both units feature advanced audio processing, allowing users to mix and switch audio sources seamlessly. They come equipped with Extron's patented audio algorithms, which help maintain high audio fidelity by eliminating noise and distortion during the switching process.

The HSA series also ensures user-friendly operation through their intuitive interface, which includes front panel controls and LED indicators for easy status monitoring. Additionally, they can be integrated into larger systems using various control options, including serial and Ethernet for automation versatility.

On the other hand, the RGB 580xi AAP is a state-of-the-art presentation switcher that provides comprehensive input options for a variety of signal sources, such as RGB, HDMI, and composite video. It is particularly notable for its ability to support high-resolution signals up to 1920x1200, catering to the needs of modern displays and projectors. The RGB 580xi AAP is designed with advanced scaling technology, ensuring that output images maintain quality and clarity, regardless of the source resolution.

This model also accommodates multiple output formats, enabling simultaneous connections to different display types. The integration of Extron's standout technologies like frame synchronizers ensures smooth transitions and real-time video switching without lag, making it an ideal choice for dynamic presentations.

Overall, Extron's HSA 400, HSA 402, and RGB 580xi AAP are exemplars of audio and video technology designed for professional environments. Their robust feature sets, including seamless switching, high-quality processing, versatile input/output options, and user-friendly interfaces, make them essential components for modern AV installations.