Extron electronic HSA 400, HSA 402 Maintenance and Modifications, cont’d Replacing the Bezels

Page 16

Maintenance and Modifications, cont’d

Replacing the Bezels

The HSA ships with RJ-45/RJ-11 connector bezel plug-ins in a variety of colors and a black, blank bezel. Replace a bezel as follows:

1.

Remove the four hex head screws on the

 

right and left sides of the front panel

 

(figure 3-1). Retain the screws. Lift the

 

panel away from the enclosure.

2.

With an Extron Tweeker or a small

 

screwdriver, push down on and gently

 

twist on the front of each connector detent

 

to disconnect the connector from the rear

 

of the front panel plug-in.

3.

Pinch the top and bottom bezel detents together

 

and push the bezel through the front panel.

4.

Snap a replacement bezel in place. If necessary, replace the

 

connector icon by prying the old icon off of the connector

 

plug-in with a Tweeker (figure 3-3) and snapping a new

 

icon in place.

Icon Label

Figure 3-3 — Changing the connector icon

5.

Snap the internal RJ-45 connector onto the back of the front

 

panel enclosure bezel plug-in.

6.

Replace the front panel in the surface mount enclosure and

 

secure it in place with the hex head screws that were

 

removed in step 1.

Removing and Replacing the Enclosure

The procedure for replacing the gas lift requires removing the HSA 400 or HSA 402 from the table. Adjusting the top surface level may also require removal of the HSA from the table.

Remove and replace the surface mount enclosure as follows:

 

 

 

 

Ensure that AC power is disconnected before

 

 

 

 

servicing the HSA unit.

1.

On the underside of the clamshell and in the enclosure, cut

 

the tie wraps that route the AAP cables out of the way.

2.

Disconnect the IEC power cord and the RJ-45 connectors

 

from the underside of the surface mount enclosure.

3.

Through the access hole in the rear of the enclosure,

 

disconnect the 3-prong cable connector on the interior AC

 

cable (figure 3-4).

Figure 3-4 — Disconnecting the interior AC cable

4.

On front panel, remove the four hex head screws on the

 

right and left sides of the front panel (figure 3-1). Retain

 

the screws. Lift the panel away from the

 

enclosure as far as the connected cables

 

allow.

 

Ensure that the edges of the connector

 

panels do not scratch the finished

 

surface of the top panel flange when

 

removing the panels.

5.

With an Extron Tweeker, push down on and

 

gently twist on the front of each connector

 

detent to disconnect the connector from the

 

rear of the front panel bezel plug-in.

3-4

HSA 400/402 Series • Maintenance and Modifications

HSA 400/402 Series • Maintenance and Modifications

3-5

Image 16
Contents HSA 400 & HSA 402 US/Domestic Precautions s Table of Contents Table of Contents, cont’d HSA 400/402 Series Surface Access ProductsIntroduction Features About the Hideaway Surface Access ProductsIntroduction Installation Introduction, cont’dInstallation Overview InstallationPreparing the Routing Template Template when the installation is complete. Save it For installing other HSA products of the same sizeOther installation surface. Mark the location Place the mounting template assembly on the tableInstallation, cont’d Cabling and Installing the AAPsCabling the Enclosure Mounting an AAP device to an HSA 400 US front panelCable access holes Only connectors 1A and 1B are present on the HSAInstallation, cont’d Routing the AAP Cables BezelsMaintenance and Modifications ThreeMaintenance and Modifications Replacing an AAPMaintenance and Modifications, cont’d Replacing the Bezels Removing and Replacing the EnclosureMaintenance and Modifications, cont’d When the HSA 400/402 is upside-down, the latch May be ineffective. If the latch releases, the enclosureWill tip and could damage the flanged edges. Keep a Hand on the enclosure to keep it from tippingAAppendix a Reference InformationSpecifications Reference InformationReplacement Parts and Accessories Interface AccessoriesReference Information, cont’d HSA Part Numbers Included PartsReference Information, cont’d Top Plate Dimensions US ModelReference Information, cont’d 15.05 + 0.083 cmPackaging for Shipment Reference Information,Internationalc t’d ModelAre sharp when the HSA is removed from the table Exercise caution when handling to prevent personalPackaging for Shipment Flanged edges of the top of the surface enclosureFigure B-4 Installing protective strips Packaging for Shipment, cont’dFigure B-6 HSA suspended in the foam Vertical Foams
Related manuals
Manual 28 pages 1.18 Kb

HSA 400 INTERNATIONAL, HSA 402 INTERNATIONAL, HSA 402, HSA 400 specifications

Extron is a well-known company specializing in the design and manufacturing of high-quality AV signal routing, distribution, and control solutions. Among its impressive lineup, the Extron HSA 400 and HSA 402 models, as well as the RGB 580xi AAP, stand out for their exceptional performance and versatility in audio and video integration.

Starting with the HSA 400 and HSA 402, these are high-performance audio switches designed for efficient audio management in professional AV environments. The HSA 400 supports up to four stereo audio input channels, while the HSA 402 expands this capability to two outputs. Both units feature advanced audio processing, allowing users to mix and switch audio sources seamlessly. They come equipped with Extron's patented audio algorithms, which help maintain high audio fidelity by eliminating noise and distortion during the switching process.

The HSA series also ensures user-friendly operation through their intuitive interface, which includes front panel controls and LED indicators for easy status monitoring. Additionally, they can be integrated into larger systems using various control options, including serial and Ethernet for automation versatility.

On the other hand, the RGB 580xi AAP is a state-of-the-art presentation switcher that provides comprehensive input options for a variety of signal sources, such as RGB, HDMI, and composite video. It is particularly notable for its ability to support high-resolution signals up to 1920x1200, catering to the needs of modern displays and projectors. The RGB 580xi AAP is designed with advanced scaling technology, ensuring that output images maintain quality and clarity, regardless of the source resolution.

This model also accommodates multiple output formats, enabling simultaneous connections to different display types. The integration of Extron's standout technologies like frame synchronizers ensures smooth transitions and real-time video switching without lag, making it an ideal choice for dynamic presentations.

Overall, Extron's HSA 400, HSA 402, and RGB 580xi AAP are exemplars of audio and video technology designed for professional environments. Their robust feature sets, including seamless switching, high-quality processing, versatile input/output options, and user-friendly interfaces, make them essential components for modern AV installations.