Extron electronic DVS 605 Configuring the DVS, Front Panel Menu System, Internal Web pages

Page 3

Configuring the DVS 605

DVS 605 devices can be configured by any of the following: via the front panel, via the internal web pages, or via RS-232/Ethernet or USB connection, using the SIS commands (see the rear page).

Front Panel Menu System

The scaler has seven front panel configuration menus: • User Presets • Picture Control • Input Configuration • Output Configuration

Audio Configuration • Advanced Configuration • View Comm Settings • Exit Menu. A hidden menu (Edit Comm Settings) is also accessible (see note after the following figure).

 

Default Display Cycle

Menu

USER

Menu

PICTURE

Menu

INPUT

Menu

OUTPUT

 

 

 

 

 

2

 

 

 

 

PRESETS

 

CONTROL

 

CONFIG

 

 

 

CONFIG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

RGBHV

 

 

 

sec.

IN

31.47 kHz

 

 

 

 

 

 

 

 

 

 

#1

 

 

 

 

 

 

 

#1

59.94 Hz

 

 

 

 

 

 

 

 

 

 

640x480

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 sec.

 

 

 

OUTPUT

 

2 sec.

 

AUDIO

Menu

ADVANCED

Menu

VIEW COMM

Menu

EXIT MENU?

 

 

 

 

 

 

 

 

 

 

 

 

720p@60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIG

 

CONFIG

 

SETTINGS

 

 

PRESS NEXT

Menu

Menu

Next

 

Next

NOTE: To access the hidden Edit Comm Settings menu, press and hold the Input 5 and the Next button simultaneously. Release buttons when

the menu appears. Edit the setting as needed, then press Menu to exit and save the settings.

To use any menu, press the Menu button to access the main menu, then repeatedly press the Menu button to cycle through to the desired menu. Press the Next button to enter and cycle through the desired submenu.

NOTE: Press Menu at any time to exit a submenu and return to the main menu.

For detailed information on the menus, see the DVS 605 User Guide, available online at www.extron.com.

To configure the DVS 605 using the front panel, follow the steps below:

1.

Within the Output Configuration menu, use the Adjust knobs to select the output resolution and refresh rate, the output signal

 

type, and the sync polarity to match the requirements of the analog display device. The HDMI format can be set to match the

 

connected HDMI display.

2.

From the Advanced Configuration menu, Test Pattern submenu, select the Alternating Pixels (Alt. Pixels) test pattern. Adjust the

 

connected analog display active pixels (size), total pixels (clocking), and pixel phase (fine sync) settings for optimal picture quality.

3.

From the Advanced Configuration menu, change the test pattern to Crop, and adjust the image position settings until all four sides

 

of the crop pattern are visible. Disable the test pattern. No further adjustments or Auto-Image functions should be performed on the

 

display device itself.

4.

Use the Advanced Configuration menu to set the Aspect Ratio (Fill or Follow) for each input. Rotate either Adjust knob to the desired

 

setting.

5.

Perform an Auto-Image on each DVS 605 input. Auto-Image is a quick way to size an input to fit the current window size.

 

To perform Auto-Image on the current input, press the Auto-Image button, then press it again to confirm.

NOTE: Alternatively using the Input Configuration menu, make any desired advanced adjustments, including turning on or off Film detection,

 

Horizontal and Vertical Start, Active Lines, Pixel Phase, and EDID setting selection.

6.

Adjust the Overscan mode under the Advanced Configuration menu as required. Overscan masks Closed Caption and ancillary data

 

common on broadcast signals. (Applies to SMPTE input resolutions only.)

7.

Use the Picture Control buttons to adjust the Horizontal and Vertical Position and Size, Brightness and Contrast, Color and Tint, and

 

Detail settings if needed.

8.

Use the User Presets menu to save the adjustments to each input for manual recall later.

Internal Web pages

The DVS 605 can be configured, controlled, and operated through the Ethernet port when connected to a LAN or WAN, using a web browser such as Microsoft® Internet Explorer®. The browser displays the factory-installed web pages, which provide a means of viewing and operating the device. Access the HTML pages by entering the IP address of the unit in the browser Address field.

NOTE: If the system administrator has not changed it, the factory default IP address is 192.168.254.254. DHCP is disabled. If the unit is

password-protected, enter the administrator or user password in the Password field.

A user name entry is required. Enter admin for administrator level or user for user level (all lower case letters).

3

Image 3
Contents Installation Rear Panel FeaturesMounting and Cabling Front Panel Overview Powering UpSetting the Front Panel Locks Executive Modes Enabling or disabling Executive mode 2 from the front panelConnected Hdmi display Configuring the DVSFront Panel Menu System Internal Web pagesEX1 CI IpiX1 Upgrading the Firmware Using the Web PagesX2@ IdhX1