Extron electronic HSA 400 Opening in the table for the HSA should be cut, Enclosure, Furniture

Page 9

Installation, cont’d

Preparing the Table and Mounting the Enclosure

The preferred and recommended method for preparing the table is to use the appropriate Extron metal routing template and a router. The templates are available at no cost. See the part numbers for the templates in appendix A, “Reference Information”.

Alternatively, you can use a paper cut-out template (see appendix A, “Reference Information”) and a sabre saw or keyhole saw, but this method is not recommended.

Prepare the table as follows:

 

CAUTION

The opening in the table for the HSA should be cut

 

 

 

only by licensed and bonded craftspeople. Exercise

 

 

 

care to prevent scarring or damaging the furniture.

 

 

 

The routing templates for the various HSA models

 

 

 

are not interchangeable. If you use the wrong

 

 

 

template, you will cut an improperly-sized hole. If

 

 

 

you use a larger template than required, the cut will

 

 

 

result in gaps in the table surface on either side of

 

 

 

the enclosure.

 

 

 

The surfaces of the HSA enclosure have screws and

 

 

 

other protruding hardware that could damage fine

 

 

 

furniture. Do not rest the enclosure on unprotected

 

 

 

furniture.

 

 

The metal routing template is reusable. Do not discard

 

 

 

 

the template when the installation is complete. Save it

 

 

for installing other HSA products of the same size.

1.

Locate the desired mounting location on the tabletop or

 

other installation surface. Mark the location.

 

 

Ensure that only the wooden strips on the routing

 

CAUTION

 

 

 

template contact the furniture. Failure to do so may

 

 

 

mar the furniture.

2.

Place the mounting template assembly on the table,

 

centered on the mounting location. Angle the template for

 

the optimum positioning. If necessary, use a square to

 

ensure that the template is properly positioned. Extron is

 

not responsible for improperly-positioned HSA products.

3.

Once the template assembly is positioned properly, secure

 

the assembly to the table with C-clamps (figure 2-2).

Figure 2-2 — Cutting the opening with a router

 

 

 

 

 

Wear safety glasses when operating the router.

 

 

 

 

 

Failure to comply can result in eye injury.

4.

Using a router with a 5/8" (or 16 mm) outside diameter

 

guide bushing and a 1/2" (or 12 mm or 12.7 mm) diameter

 

straight router bit, carefully cut the opening in the table

 

surface (figure 2-2).

5.

Remove the C-clamps and the routing template.

 

 

 

 

 

The flanged edges of the top of the surface enclosure

 

 

 

 

 

 

 

 

 

are sharp. To prevent personal injury, exercise

 

 

 

 

 

caution when the HSA is not installed in a table.

 

 

 

The flanged edges of the top of the surface enclosure

 

CAUTION

 

 

 

 

 

 

are bevelled to an ultra-fine thickness of less than

0.04(4/100)" (approximately 1 mm). These edges are soft and can be easily nicked or bent. Exercise caution when handling and mounting the enclosure. Mishandling can damage the appearance of the enclosure.

6. Remove the plastic strips that protect the flanged edges of the top of the surface enclosure. If a sticky residue remains, remove it with an appropriate metal cleaning product.

CAUTION

Do not use isopropyl alcohol or other solvents to

 

clean the HSA. Strong solvents will ruin some

 

finishes.

2-4

HSA 400/402 Series • Installation

HSA 400/402 Series • Installation

2-5

Image 9
Contents User’s Manual Extron’s Warranty PrecautionsPage Table of Contents Table of Contents, cont’d HSA 400/402 Series Surface Access ProductsOne IntroductionAbout the Hideaway Surface Access Products FeaturesIntroduction Installation TwoIntroduction, cont’d Installation Installation OverviewPreparing the Routing Template For installing other HSA products of the same size Template when the installation is complete. Save itOther installation surface. Mark the location Place the mounting template assembly on the tableCabling and Installing the AAPs Installation, cont’dMounting an AAP device to an HSA 400 US front panel Cabling the EnclosureAn RJ-11 plug can be connected to the RJ-45 jack Only connectors 1A and 1B are present on the HSABezels Installation, cont’d Routing the AAP CablesThree Maintenance and ModificationsReplacing an AAP Maintenance and ModificationsRemoving and Replacing the Enclosure Maintenance and Modifications, cont’d Replacing the BezelsMaintenance and Modifications, cont’d May be ineffective. If the latch releases, When the HSA 400/402 is upside-down, the latchEnclosure will tip and could damage the flanged Edges. Keep a hand on the enclosure to keep it fromReference Information AAppendix aReference Information SpecificationsInterface Accessories Replacement Parts and AccessoriesReference Information, cont’d HSA Part Numbers Included PartsUS Model Reference Information, cont’d Top Plate Dimensions15.05 + 0.083 cm Reference Information, cont’dAppendixBB Packaging for ShipmentReference Information,Internationalc t’d Model Exercise caution when handling to prevent personal Are sharp when the HSA is removed from the tablePackaging for Shipment InjuryPackaging for Shipment, cont’d Figure B-4 Installing protective stripsFigure B-6 HSA suspended in the foam Vertical Foams
Related manuals
Manual 28 pages 13.51 Kb

RGB 580xi AAP, HSA 402, HSA 400 specifications

Extron is a well-known company specializing in the design and manufacturing of high-quality AV signal routing, distribution, and control solutions. Among its impressive lineup, the Extron HSA 400 and HSA 402 models, as well as the RGB 580xi AAP, stand out for their exceptional performance and versatility in audio and video integration.

Starting with the HSA 400 and HSA 402, these are high-performance audio switches designed for efficient audio management in professional AV environments. The HSA 400 supports up to four stereo audio input channels, while the HSA 402 expands this capability to two outputs. Both units feature advanced audio processing, allowing users to mix and switch audio sources seamlessly. They come equipped with Extron's patented audio algorithms, which help maintain high audio fidelity by eliminating noise and distortion during the switching process.

The HSA series also ensures user-friendly operation through their intuitive interface, which includes front panel controls and LED indicators for easy status monitoring. Additionally, they can be integrated into larger systems using various control options, including serial and Ethernet for automation versatility.

On the other hand, the RGB 580xi AAP is a state-of-the-art presentation switcher that provides comprehensive input options for a variety of signal sources, such as RGB, HDMI, and composite video. It is particularly notable for its ability to support high-resolution signals up to 1920x1200, catering to the needs of modern displays and projectors. The RGB 580xi AAP is designed with advanced scaling technology, ensuring that output images maintain quality and clarity, regardless of the source resolution.

This model also accommodates multiple output formats, enabling simultaneous connections to different display types. The integration of Extron's standout technologies like frame synchronizers ensures smooth transitions and real-time video switching without lag, making it an ideal choice for dynamic presentations.

Overall, Extron's HSA 400, HSA 402, and RGB 580xi AAP are exemplars of audio and video technology designed for professional environments. Their robust feature sets, including seamless switching, high-quality processing, versatile input/output options, and user-friendly interfaces, make them essential components for modern AV installations.