Extron electronic CTR 8 Symbols Used in this Guide, Error Messages, Ascii to HEX Conversion Table

Page 12

Symbols Used in this Guide

When programming in the field, certain characters are most conveniently represented by their hexadecimal rather than their ASCII values. The table below shows the hexadecimal equivalent of each ASCII character:

ASCII to HEX Conversion Table

Space

.

Table 1. ASCII to HEX Conversion Table

] — carriage return with line feed

}— carriage return (no line feed)

• — space character E — Escape key

The X/ values defined in this section are the variables used in the Command Response Table. X) — Input 0-8

X@ — Input selection status 0 = Not Selected 1 = Selected

X# — A/V mute mode

0 = Normal operation, no muting (default)

1 = Channel 0 A/V mute (0!)

2 = Video Mute (1B) and Audio Mute (1Z)

3 = Video and Sync Mute (2B)

X$ — Mute LED mode

0 = Always on (default)

1 = Off when muted

2 = Blink when muted

X2% — Baud rate: 9600, 19200, 38400, 57600 (default = 9600)

NOTE: Unless otherwise indicated, commands are not case-sensitive.

Error Messages

E01 — Invalid output channel number (too large)

E10 — Invalid command

E13 — Invalid value (too large)

CTR 8 • Remote Communication and Control

7

Image 12
Contents CTR Sicherheitsanweisungen Deutsch Instrucciones de seguridad EspañolÈíñòðóêöèÿ ïî òåõíèêå áåçîïàñíîñòè Ðóññêèé FCC Class a Notice Registered TrademarksTrademarks Specifications Availability Software CommandsConventions Used in this Guide NotificationsContents Features IntroductionAbout the CTR Front Panel Features Rear Panel Features and CablingConnectors see next Panels CablingPower Connection = Ground pinApplication Diagrams Application with Show Me CablesApplication with Individual Contact Closure Switch Application with CCR 4BLBSolder Cups Using Simple Instruction Set SIS Commands Remote Communication ControlHost-to-CTR 8 Communications CTR 8-Initiated MessagesSymbols Used in this Guide Error MessagesAscii to HEX Conversion Table Command and Response Table for SIS Commands MutingMute Modes Button Input Button State Mute Mute mode Number Mode LED Responses for Video MutingDownloading and Installing Firmware Loader Updating FirmwareInstalling Firmware with Firmware Loader Downloading CTR 8 FirmwareOpening Firmware Loader Add Next Select Edit Remove Selected Devices from the toolbar Tabletop Placement MountingRack Mounting Under-desk and Furniture MountingUSA, Canada, South America Japan Europe and Africa ChinaAsia Middle East