Extron electronic CTR 8 manual Command and Response Table for SIS Commands, Muting, Mute Modes

Page 13

Command and Response Table for SIS Commands

Command

ASCII Command

Response

Additional

 

(host to unit)

(unit to host)

Description

 

 

 

 

Select input

X)!

ChnX)]

X) = input 0-8

View last selected input

!

X)]

 

Query contact closure status

S/s

X@X@X@X@X@X@X@X@]

Least significant input

 

 

 

on far left

Example response:

 

01000000]

Contact input 2 is

 

 

 

selected

Unidirectional Serial Data Port

 

 

Configure port parameters

E2*X2%,n,8,1CP}

Cpn02CcpX2%,n,8,1]

n = Parity = None

Example command:

E2*19200,n,8,1CP }

 

8 = Data bits

 

 

 

1 = Stop bit

View parameters

E2CP}

X2%,n,8,1]

 

 

 

 

 

A/V Mute Mode

 

 

 

Configure A/V mute mode

EX#*X$MUTM}

MutmX#*X$]

 

View A/V mute mode setting

EMUTM}

X#*X$]

 

 

 

 

 

Other

 

 

 

Information request

I/i

CTR8]

 

Request part number

N/n

60-xxxx-xx]

View the part number

Query firmware version

Q/q

x.xx]

Firmware build (2

 

 

 

decimal places)

Query full firmware version

*Q/*q

x.xx.xxxx]

View the full firmware

Reset all device settings to

EzXXX}

Zpx]

 

factory

 

 

 

A/V Muting

The CTR 8 allows A/V muting for a selected input. This feature allows users to press the selected input button to mute and unmute the audio and video as needed during a presentation.

Press the button once to select an input (Select state)

Press the same button again to activate A/V mute (De-select state)

Press the button once more to return to the Select state, which selects the input and unmutes the audio and video.

NOTE: The A/V mute feature is only triggered by contact closure. SIS input selection (for example, entering 1! two times) will not trigger the de-select state.

A/V Mute Modes

There are three A/V mute modes, based on the device:

Mute mode 1: Mutes switcher input by selecting channel 0

Mute mode 2: Mutes video and audio individually

Mute mode 3: Mutes video and sync

Mute mode 0 is the normal (default) single state operation. A/V mute is not activated in this mode.

NOTE: See the next page for a partial list of Extron switchers that are compatible with the different mute modes.

CTR 8 • Remote Communication and Control

8

Image 13
Contents CTR Instrucciones de seguridad Español Sicherheitsanweisungen DeutschÈíñòðóêöèÿ ïî òåõíèêå áåçîïàñíîñòè Ðóññêèé Registered Trademarks FCC Class a NoticeTrademarks Software Commands Specifications AvailabilityConventions Used in this Guide NotificationsContents Introduction FeaturesAbout the CTR Rear Panel Features and Cabling Front Panel FeaturesConnectors see next Panels Cabling= Ground pin Power ConnectionApplication with Show Me Cables Application DiagramsApplication with CCR 4BLB Application with Individual Contact Closure SwitchSolder Cups Remote Communication Control Using Simple Instruction Set SIS CommandsHost-to-CTR 8 Communications CTR 8-Initiated MessagesError Messages Symbols Used in this GuideAscii to HEX Conversion Table Muting Command and Response Table for SIS CommandsMute Modes LED Responses for Video Muting Button Input Button State Mute Mute mode Number ModeUpdating Firmware Downloading and Installing Firmware LoaderDownloading CTR 8 Firmware Installing Firmware with Firmware LoaderOpening Firmware Loader Add Next Select Edit Remove Selected Devices from the toolbar Mounting Tabletop PlacementRack Mounting Under-desk and Furniture MountingEurope and Africa China USA, Canada, South America JapanAsia Middle East