Extron electronic CIA111, CIA114 Mounting the Interfaces, When the image is displayed correctly

Page 10

Installation, cont’d

When the image is displayed correctly

Once the system has been cabled and tested, the interface can be installed in the wall or furniture. To mount the interface and install optional MAAP devices (CIA111 only), see the next section, "Mounting the Interfaces".

CThe CIA111 and CIA114 interfaces must be installed into Underwriters Laboratories (UL) approved electrical wall boxes. See the following section on UL requirements. The wall boxes are not included with the interfaces; the installer is responsible for obtaining and installing the boxes.

UL Requirements

Sound System

 

 

 

 

 

 

 

MON

ITOR

 

 

 

 

 

 

NO

 

 

E SH

IFT

 

 

 

 

 

 

IMAG

 

 

 

 

 

 

 

 

 

 

 

OUTP

UT

 

 

 

 

ITOR

 

 

 

 

MON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPU

T

 

 

 

 

 

ER

 

 

 

 

 

PUT

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

INPU

T

 

 

 

 

 

DIO

 

 

 

 

 

AU

 

 

 

 

uto

 

 

 

 

 

 

 

A

er

 

 

 

 

 

 

 

Pow

 

LAN/WAN

Network/

Internet

1 CIA11

Document

Camera

The following Underwriters Laboratories (UL) requirements listed pertain to the installation of the CIA111 and CIA114 interfaces into a wall or furniture.

1.

These units are not to be used beyond their rated voltage

 

range.

2.

These units must be installed in UL listed junction boxes.

3.

These units must be installed with conduit in accordance

 

with the National Electrical Code.

Preparing the site and installing the wall box

Presentation Monitor Extron

Local Monitor

CIA111

PC

Computer Interface

 

Figure 2-5 — Typical CIA111 application

Mounting the Interfaces

This section describes how to mount the interfaces. Follow the instructions that are appropriate to your interface.

CInstallation and service must be performed by authorized personnel only.

Mounting the CIA111 or CIA114

The CIA111 mounts to a wall or podium using a two-gang wall box. The CIA114 mounts in a one-gang wall box. The installation must conform to national and local electrical codes and to the equipment’s size requirements.

NThe CIA114 requires a minimum of 3.0” H x 2.0” W x 2.5” D space inside the wall box.

1.

Choose an installation location that will allow cable runs

 

without interference. Allow enough depth for both the

 

wall box and the cables. You may need to install the cables

 

into the wall, furniture, or conduits before installing the

 

interface.

2.

Use the appropriate template in appendix A, "Reference

 

Information", as a guide to measure and mark the hole in

 

the wall or furniture for installing the wall box.

CThe cut-out templates are not to scale and are provided for reference only. Measure the hole carefully before cutting.

3.

Check the opening size by inserting the wall box into

 

the opening. The box should fit easily into the opening.

 

Enlarge or smooth the edges of the opening, if necessary.

4.

Feed cables through the wall box punch-out holes, and

 

secure them with cable clamps to provide strain relief.

5.

Exposed cable shields (braids or foil) are potential sources

 

of short circuits. Trim back and/or insulate shields with

 

heat shrink, if needed.

WTo prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.

2-8

CIA111 and CIA114 • Installation and Operation

CIA111 and CIA114 • Installation and Operation

2-9

Image 10
Contents User’s Manual Wall Box and Floor Box Mountable InterfacesPrecautions Extron’s Warranty安全须知 中文 FCC Class a NoticeChapter Two Installation and Operation Appendix a Reference InformationTable of Contents, contd CIA111 and CIA114 Computer Video InterfaceAbout this Manual FeaturesIntroduction About the CIA111, CIA114, and CIA114F5Front Panel Features and Cabling InstallationInstallation Overview No Monitor monitor emulation button and LED If youSide Panel Features and Cabling Installation, cont’dPower adapter connection Plug the included power If the image does not appear or there is no sound Pre-installation Testing and TroubleshootingIf the image is not displayed correctly Mounting the Interfaces When the image is displayed correctlyPreparing the site and installing the wall box Mounting the CIA111 or CIA114Attaching the wall box to a wall stud Mounting optional Maap devices CIA111 onlyMounting the CIA114F5 Mounting the interface to the wall boxPreparing the site and cables Mounting the interface to the floor boxSpecifications Reference InformationCIA interface part numbers Reference Information, cont’dPart Numbers Included partsTemplates AccessoriesCables and Adapters Surface CUT-OUT Area for Furniture Mount
Related manuals
Manual 2 pages 37.19 Kb Manual 2 pages 52.73 Kb Manual 2 pages 48.11 Kb

CIA114F5, CIA111, CIA114 specifications

Extron Electronics is a renowned name in the AV control and distribution industry, and their products are designed to streamline and enhance audiovisual systems. Among their offerings are the CIA114F5, CIA111, and CIA114, each tailored to meet specific user needs while encapsulating cutting-edge technology and features.

The CIA114F5 is a high-performance, five-channel amplifier designed for distributed audio applications. One of its standout features is its ability to deliver 30 watts per channel, allowing for exceptional audio clarity and power across multiple zones. The amplifier utilizes Extron's patented Class D output technology, ensuring high efficiency and reduced heat generation, which translates to a longer lifespan and lower operational costs. The CIA114F5 also includes built-in signal processing capabilities, such as equalization and filtering, which help optimize audio performance in various environments.

Moving to the CIA111, this model is a compact, single-channel amplifier, perfect for smaller setups or individual zones in larger systems. It provides 25 watts of power, making it suitable for classrooms, conference rooms, and similar venues where clarity in sound is paramount. The CIA111 features a highly efficient design and is equipped with Extron's exclusive Energy Saver technology, which minimizes power consumption when the amplifier is not in use. This not only extends the product's life but also has a positive impact on overall energy costs.

Lastly, the CIA114 is another versatile component that provides four output channels, each capable of delivering 30 watts. This model stands out with its versatile installation options, which include mounting on a rack or against a wall. The CIA114 uses advanced circuit design to minimize distortion and provide a rich sound stage, enhancing the listening experience in various applications. Additionally, its compatibility with Extron's control systems allows for seamless integration into existing AV setups, empowering users with effortless control over audio distribution.

In summary, Extron's CIA114F5, CIA111, and CIA114 amplifiers represent the pinnacle of reliability and performance in distributed audio systems. With features like class D amplification, built-in processing, and energy-saving technologies, these models cater to a broad range of AV needs, ensuring that users receive the best possible audio experience in any environment.