Extron electronic SCP 150 AAP Specifications, s, Accessories, Dimensions, Included Parts, Cables

Page 14

Specifications, Part #s, Accessories, Dimensions

Specifications

General

Power

12VDC from the MLC 206

Temperature/humidity

Storage -40° to +158°F (-40° to +70°C) /

 

10% to 90%, non-condensing

 

Operating +32° to +122°F (0° to +50°C) /

 

10% to 90%, non-condensing

Rack mount

Yes, with optional faceplate, and

 

furniture/wall mountable with optional

 

faceplates or AAP wall plates

Enclosure type

Metal

Enclosure dimensions

 

Faceplate

1.4" H x 3.5" W x 0.1” D (3.5 cm H x 8.9

 

cm W x 0.3 cm D) (double space high AAP

 

plate)

Boards

1.3" H x 2.6" W x 0.9" D

 

(3.3 cm H x 6.6 cm W x 2.3 cm D)

 

(Depth excludes buttons. Allow at least

 

2.1” (5.3 cm) depth in the wall/furniture.)

Product weight

0.1 lbs (<0.1 kg)

Shipping weight

1 lbs (0.5 kg)

Vibration

ISTA/NSTA 1A in carton (International

 

Safe Transit Association)

Listings

UL, CUL as components of the MLC 206

Compliances

CE, FCC Class A, VCCI, AS/NZS, ICES as

 

components of the MLC 206

MTBF

30,000 hours

Warranty

3 years parts and labor

Specifications are subject to change without notice.

Included Parts

These items are included in each order for a control module:

Included parts

Part number

 

 

RCM-SC (grey, black, white)

70-183-01, -02, -03

 

 

or RCM-SCLT (grey, black, white)

70-184-01, -02, -03

3.5 mm, 5-pole captive screw connectors

10-319-10

 

 

1N4001 or equivalent diodes

 

(100mA max. current, 50V max. reverse bias)

 

for Da Lite and Draper installations

 

Relay Control Modules User’s Manual

68-631-01

 

 

Accessories

Accessories

Part number

 

 

AAP 102 (grey, black, white) (2 gang)

60-300-01, -02, -03

 

 

AAP 104 (grey, black, white) (4 gang)

60-301-01, -02, -03

 

 

Cables

Comm-link cable

Part number

 

 

50 feet/15.2 meters long

26-461-01

 

 

100 feet/30.5 meters long

26-461-02

 

 

Conductor gauges in Extron Comm-Link cables

red and black single strands (for power/ground) 18 AWG

white and violet shielded single strands (for signals) 22 AWG

drain wire

24 AWG

A-2

Relay Control Modules • Specifications, Part #s, Dimensions

Relay Control Modules • Specifications, Part #s, Dimensions

A-3

Image 14
Contents Control Accessories User’s ManualFCC Class a Notice PrecautionsExtron’s Warranty Table of Contents Introduction Table of Contents, cont’dOne Relay Control ModulesTwo Installation and OperationFeatures IntroductionUL Requirements Installation and OperationInstallation Overview Cabling MLC 206 to a Relay Control ModuleInstallation and Operation, cont’d Control ModuleTypical RCM-SCLT application MLC Relay Port Front Panel Features and Operation Setting Up the ButtonsTesting/Troubleshooting Specifications, Part Numbers Accessories, and Dimensions AAppendix aAccessories Specifications, s, Accessories, DimensionsSpecifications Included PartsSpecifications, Part Numbers, Accessories, cont’d Dimensions RCM dimensions