Installation and Operation, cont’d

4.In the Relay & Misc. Options portion of the control program, select the appropriate options for each relay.

For example, set the relays that are tied to the Screen

Position Up (), Screen Position Down (), and Stop buttons to Momentary, and select the duration for the momentary contact. For the relay that is tied to the Lighting On/Off button (RCM-SCLT only), select Latched.

5.Set each relay to (NO) Open (normally open). Refer to the MediaLink Controllers User’s Manual and the MediaLink Control Program for more information.

6.Repeat steps 3, 4, and 5 for each RCM button.

The MLC contains three relays, so you may install a maximum of one RCM-SC or one RCM-SCLT in a system with an MLC.

Testing/Troubleshooting

Before installing the control modules into the wall or furniture, test the system to make sure that the connections are correct and the modules are working correctly.

1.Connect the cables between the MLC and the control module(s), connect IR Emitters or an IR Broadcaster to the MLC (if IRCM modules are used), and connect a host computer to the MLC’s Config port. If available, cable the A/V source device(s) to the display device (projector), and connect the projector and any relay-controllable items to the MLC. Refer the MediaLink Controller User’s Manual for wiring diagrams.

2.Connect the MLC to a 12VDC power source. Connect the host computer, A/V source device(s), and projector to a power source and turn them on.

3.Start the MediaLink Control Program, and set up the control modules and the MLC (for each button set up the relays, select or type in RS-232 commands, or perform IR learning).

4.Press the buttons on the control module, watch the module’s LED (for IRCM and ACM modules), and observe the item being controlled by the module (lights, screen, projector mount, VCR, DVD, MLS switcher, etc.).

4A If the LED does not light when a button is pressed, check the captive screw connector wiring at both the MLC and the control module. If the conductor assignments are not the same at both ends, the circuits may be damaged if power is applied to the wrong pole, and the control module will not turn on. Verify that the connectors are wired identically at both ends of the cable.

4B If power is present at the MLC and at the control module, but the item being controlled does not respond when a button is pressed:

Make sure the control module’s address DIP switch settings are correct and that each module has a unique address.

For IRCM

modules, check the MediaLink

 

control software to verify that an IR command

 

has been “learned” for that button.

For IRCM

modules, verify that an IR

Emitter or IR Broadcaster has been connected to the MLC’s Display/Source Control IR connector.

2-14 Relay Control Modules • Installation and Operation

Relay Control Modules • Installation and Operation 2-15

Image 12
Contents Control Accessories User’s ManualPrecautions Extron’s WarrantyFCC Class a Notice Table of Contents Table of Contents, cont’d OneIntroduction Relay Control ModulesInstallation and Operation FeaturesTwo IntroductionInstallation and Operation Installation OverviewUL Requirements Cabling MLC 206 to a Relay Control ModuleInstallation and Operation, cont’d Control ModuleTypical RCM-SCLT application MLC Relay Port Front Panel Features and Operation Setting Up the ButtonsTesting/Troubleshooting Specifications, Part Numbers Accessories, and Dimensions AAppendix aSpecifications, s, Accessories, Dimensions SpecificationsAccessories Included PartsSpecifications, Part Numbers, Accessories, cont’d Dimensions RCM dimensions