Bosch Appliances 125HX LP specifications Maintenance and Service, Trouble Shooting, Introduction

Models: 125HX LP

1 18
Download 18 pages 57.85 Kb
Page 11
Image 11

MAINTENANCE AND SERVICE

REVIEW MAINTENANCE TABLE ON THE BACK OF THIS MANUAL.

Approximately once a year, theAquaStar should be checked and cleaned. To remove the front cover, first remove the incandescent particle tray, then pull off the temperature adjustment knob and unscrew and remove the plastic collar. Pull main cover out toward you and lift up and out. THE FOLLOWING OPERATIONS SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON:

Vent System: Should be checked annually. Clean and repair as needed.

Water Valve (Part # 8707006353): The water valve on this heater should be serviced periodically. Lubricate component 36 on page 16 with a small amount of silicon, faucet or lithium grease every two years to keep its o rings fresh and pushrod sliding smoothly. Every 3-5 years replace component 36 on page 16. The frequency will depend on the mineral content of the water and conditions of use or whenever signs of corrosion appear at the gas and water valve joint. Periodically check that the water inlet filter (#27 on page 16) is clean as well. NOTE: If water valve is removed, be sure to also inspect the o ring seals on the ends of the left and right hand side water pipes before re-installing. Lubricating the o rings is recommended.

Pilot Flame: The pilot flame should burn with a clean, sharp, blue flame and should resemble the diagram in Fig.10. If the flame is soft and yellow, the pilot burner orifice may need to be cleaned or replaced. The pilot flame should be approximately 2 inches long, extending past the flame sensor. If the flame is too small, it will not reach the flame sensor and the burners will not come on.

3mm

Correct gap between pilot burner tip and electrode tip

Piezo Electrode

Flame sensor

Piezo

Electrode

Fig. 10 - Characteristic Pilot Flame

To clean the pilot burner and/ or the pilot orifice : Turn

off the gas to the unit. Set the On/Off switch to Off (position

). Remove the cover of the heater. To do so, pull off the temperature adjustment knob and unscrew and remove the plastic collar. Pull main cover out toward you and lift up and out. The pilot orifice should be cleaned or replaced. Do not enlarge the orifice.

Do not use any wire or sharp object to clean orifices. Natural gas orifices are large enough that you can usually clean them by blowing through them. LP orifices, on the other hand, are too small to clean and should be replaced.

To access the pilot orifice, remove 2 screws holding pilot assembly in place. Then loosen compression fittings to expose pilot orifice.

PILOT ORIFICE

Fig. 11 - Pilot burner with pilot orifice

Main Burner Flames: The main burner flames should be blue, with a more intense blue cone in the center core. Yellow flames could be a sign of wrong size gas orifices or dirty burners, or a blockage on the heat exchangers fins. If some burners have yellow flames while others have good flames, it is likely that dust, lint or spider webs have partially clogged the burner venturis. To clean the burners, contact a gas service person.

Mineral Scale Build-up: The AquaStars heater, when operated at lower temperature settings, do not accumulate mineral build-up. If however, the heater is used at the higher temperature settings and the water has a high mineral content, periodic descaling may be necessary. The heating coils should be flushed with a descaling solution. The descaling is done only to the heat exchanger. The chemicals will damage the hydro-generator and other parts. Consult your dealer or Controlled Energy for instructions.

TROUBLE SHOOTING

Introduction

The AquaStar 125HX burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up in faucet aerators, or shower heads; Uneven pressures between cold and hot. (with single lever faucets) Plumbing cross overs. These water flow related problems can cause the heater to deliver less than its full output, or to fail to ignite or to shut down completely.

6 720 606 562 (02.03)

11

Page 11
Image 11
Bosch Appliances 125HX LP Maintenance and Service, Trouble Shooting, Review Maintenance Table on the Back of this Manual

125HX LP specifications

The Bosch Appliances 125HX LP is an outstanding addition to any modern kitchen, exemplifying innovation and efficiency in kitchen technology. Renowned for their commitment to quality and performance, Bosch has crafted this model to meet the needs of both amateur and professional chefs.

One of the standout features of the 125HX LP is its powerful cooking capabilities. The model is equipped with a high-efficiency burner that provides intense heat for rapid cooking and precise temperature control. This is particularly beneficial when searing meats or preparing gourmet dishes, allowing users to achieve professional-grade results at home.

Another significant characteristic of the 125HX LP is its sleek and durable design. Constructed with premium materials, this appliance not only enhances the aesthetic appeal of your kitchen but also promises longevity. The stainless steel finish is not only attractive but also easy to clean, ensuring that the appliance maintains its polished look over time.

In terms of user-friendly technology, Bosch has integrated advanced features such as an intuitive control panel. This panel provides clear visibility and ease of access to various cooking settings while offering precise temperature adjustments. The 125HX LP also includes an automatic ignition system, which ensures that lighting the burners is both quick and safe, reducing the risk of accidents.

Safety is a major consideration in the design of the 125HX LP. The appliance features flame failure detection which automatically shuts off the gas supply if the flame goes out, providing peace of mind during use. Additionally, the cooking surface is designed to minimize the risk of burns, making it ideal for families.

The Bosch Appliances 125HX LP stands out with its commitment to energy efficiency. The model is designed to reduce energy consumption without compromising performance, making it an eco-friendly choice for the environmentally conscious consumer.

In summary, the Bosch Appliances 125HX LP combines power, design, and safety features to deliver a superior cooking experience. With its advanced technology and user-oriented features, this model is perfect for those who prioritize functionality and style in their kitchen appliances. Whether a casual cook or a culinary enthusiast, the Bosch 125HX LP is sure to meet and exceed expectations and stand the test of time in any kitchen environment.