ATTO Technology FC-44ES, FC-42ES, FC-41ES, FC-41EL, FC-42XS, FC-41XS, FC-21PS Glossary

Page 12

2 Fibre Channel is a key technology for storage

Fibre Channel is a serial communications technology designed to transfer large amounts of data among a variety of hardware systems over long distances. It is a key technology for applications that require shared, high bandwidth access to storage.

Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device. It moves buffer contents from one port to another, without regard to the format or meaning of the data so different upper level

protocols are able to run over Fibre Channel hardware.

The Fibre Channel architecture is structured as a hierarchical set of protocol layers. Defined within these layers are rules for signal interfaces, serial encoding and decoding, error control, frame format and communications protocols.

Glossary

Some terms used in the Fibre Channel industry are defined below. More information is available through the ATTO Technology website (www.attotech.com), the Fibre Channel Industry Association (www.fibrechannel.com), Cern (www.cern.ch), the Storage Area Networking Industry Association

(www.snia.org), and the Fibre Channel Consortium (www.iol.unh.edu/consortiums, click on FC).

Term

Definition

ANSI

American National Standards Institute

arbitrate

process of selecting one L_Port from a collection of ports which ask for use of the arbitrated loop

 

at the same time

arbitrated loop

a loop topology (FC-AL) in which two or more ports are interconnected, but only two ports can

 

communicate at one time; low-cost solution which may or may not use hubs and switches

auto negotiation

hardware senses and automatically responds depending on configuration

BER

Bit Error Rate: a measure of transmission accuracy; the ratio of bits received in error to bits sent

bit

smallest unit of data a computer can process: a single binary digit with a value of either 0 or 1

bus

a collection of unbroken signal lines used to transmit information from one part of a computer

 

system to another; taps on the lines connect devices to the bus

byte

an ordered set of 8 bits

channel

a point-to-point link which transports data from one point to another

CPU

Central Processing Unit: the portion of the computer that actually performs computations

CRC

Cyclic Redundancy Check: an error-correcting code which calculates a numeric value for received

 

and transmitted data; if no error has occurred during transmission, the CRC for both received and

 

transmitted data should be the same

destination

a value in the frame header of each frame which identifies the port in the node where the frame is

address

being sent

device driver

a program that allows a microprocessor to direct the operation of a peripheral device

DMA

Direct Memory Access: a way to move data from a storage device directly to RAM without using

 

the CPU’s resources

DMA bus master

allows a peripheral to control the flow of data to and from system memory by block as opposed to

 

allowing the processor to control the data by bytes (PIO or programmed I/O)

9 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual

Image 12
Contents Atto Celerity Fibre Channel Host Adapters Atto Technology, Inc Contents Atto provides Fibre Channel solutions Celerity FC-44ES AdapterCelerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-41EL Adapter PCI bus specifications Celerity FC-42XS AdapterCelerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity selection guide Fibre Channel is a key technology for storage GlossaryTerm Definition LED Installing and updating drivers Specialized configurationsWindows 2000/XP/Server 2003/Vista Adding a Celerity FC adapter to an existing installation Creating a boot diskClick on Install Driver Upgrading an existing Celerity FC driverMac OS X driver installation, update Linux driver installation, updateCreating a Celerity FC installation floppy Creating a floppy disk from a downloadPage Hardware installation InstallationSystem requirements Fibre Channel addressBracket details Page Adapter board details Exhibit 4-10 FC-41ES Exhibit 4-12 FC-42XS Exhibit 4-13 FC-41XS Exhibit 4-14 FC-21PS Launch the Configuration Tool Updating hardware flashUpdating flash in all operating systems Updating flash on a PCTroubleshooting Mac OSGeneral suggestions Linux Select PropertiesSelect Device Manager Appendix a Standards and compliances FCC standards radio and television interferenceCanadian standards European standardsFollowing apply to the Celerity FC-42XS host adapter only Appendix B Accessories Ultra 320 Scsi Product Features Appendix C Scsi adapter selection guide12.5 Product Features Atto ExpressSAS RAID Adapters R348 R380 Appendix D SAS adapter selection guideAppendix E Safety, warranty, contacts SafetyAtto Technology, Inc. limited warranty Operation