Addonics Technologies Z4SNHU3 manual Port Multiplier, Default factory DIP Switch setting, Bzs Ez

Page 3

Port Multiplier

Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

BZS – Error buzzer function

EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start.

M2 – RAID mode 2

M1 – RAID mode 1

M0 – RAID mode 0

OFF

OFF

OFF

OFF

OFF

SW1

1

2

3

4

5

BZS EZ

M2 M1 M0

1.Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

2.Auto-rebuilding to spare drive is DISABLED (EZ)

3.Individual drive mode is ENABLED (M0~M2)

 

 

 

Dip Switch Settings

 

 

 

 

 

 

 

 

 

 

 

Raid Mode

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

Individual Drive

OFF

OFF

OFF

OFF

OFF

 

 

(Factory Default)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

OFF

OFF

ON

ON

ON

1 and 10

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

3

5

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

Clone

Large

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

Enable

Auto-

Port Multiplier Mode

ERR Buzzer

Rebuilding

 

Function

to Spare

 

 

Drive

 

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)

Phone: 408-453-6212

Email: www.addonics.com/support/query/