Mounting

Your equipment may be rackmounted in 4-post rack enclosures using the included rack shelves and the following suggested mounting procedures, which should be used instead of the procedures described in your Owner's Manual (if any). These procedures are for common enclosure types and may not be appropriate for all rack enclosures. You must determine the fitness of rackmount hardware and procedures before mounting. If this hardware or these procedures are not suitable for your application, contact your rack enclosure's manufacturer for a solution.

Mount one piece of equipment in a 4-post rack section using the Single Unit Installation procedure, or one piece of equipment in a 2-post rack using the 2-Post (Telecom) Installation procedure. If you have two UPSRMRII shelf kits and a sufficiently deep rack, you may mount two pieces of equipment in a 4-post rack section using the Back to Back Installation procedure.

Single Unit Installation

1Connect the two segments of each shelf (A) using the included screws and nuts (B). Leave the screws slightly loose so that the shelves can be adjusted in the next step.

2Adjust each shelf to fit your rack, then mount them in the lowest available space of your rack with the screws, nuts and washers provided (C). Note that the support ledges should face inward. Tighten the screws that connect the shelf segments (B).

 

B

1

A

 

C

 

2

B

 

3Attach mounting ears (D) to the front mounting holes of your equipment (E) using the screws provided (F). The ears should face forward.

4Using an assistant if necessary, lift yourequipment and slide it onto the mounting shelves. Attach your equipment to the rack by passing the screws, nuts and washers provided (G) through its mounting ears andinto the rack rails.

E

3

D

F

 

G

 

4

 

 

3

Image 3
Contents SmartOnline Important Safety Warnings Mounting Single Unit InstallationBack-to-Back Installation Post Telecom Installation UPS Front Panel Controls FeaturesBattery Pack Rear Panel UPS Rear PanelIsolation Transformer Rear Panel Features Connection Hardwire your UPS’s output to your equipmentAC Output Voltage Diagram Connect communication cables to your UPS optional DRY Contact Interface DiagramTo turn the UPS and transformer OFF Configure your UPS’s outputTurn input to the UPS on Turn UPS output onOperation Startup Self-TestFailed Self-Test On Battery Alarm Normal OperationOverload Messages Shutdown Messages Bypass MessagesService/Warranty and Insurance ServiceYear Limited Warranty SU10KRT3U Specifications