Tripp Lite AVR Series, AVR550U Surge / Noise Suppression, Physical, Environmental, Communications

Page 3

Switches

Combination power off / on / self-test push button switch

SURGE / NOISE SUPPRESSION

AC surge suppression

400 joules

 

 

Dataline suppression

Tel/DSL

 

 

EMI / RFI AC noise

Yes

suppression

 

 

 

PHYSICAL

 

Shipping weight (lbs)

14.25

 

 

Shipping weight (kg)

6.47

 

 

Shipping Dimensions

4.75 x 13.5 x 8.75

(HWD/in)

 

 

 

Shipping Dimensions

12.07 x 34.29 x 22.23

(HWD/cm)

 

 

 

Unit weight (lbs)

10.95

 

 

Unit weight (kg)

4.97

 

 

Unit Dimensions

3.5 x 11.25 x 6

(HWD/in)

 

 

 

Unit Dimensions

8.89 x 28.56 x 15.24

(HWD/cm)

 

 

 

Material of

ABS

construction

 

 

 

Form factors

Ultra-compact

supported

 

 

 

Battery Access

Hot-swappable batteries are accessible via battery door

 

 

ENVIRONMENTAL

 

Relative Humidity

0 to 95%, non-condensing

 

 

Storage Temperature

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

 

 

Operating

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Temperature

 

 

 

COMMUNICATIONS

 

Network monitoring

USB (HID)

port

 

 

 

Software and cabling

Includes USB cable and PowerAlert UPS monitoring software

included

 

 

 

WatchDog

Yes, compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft

compatibility

reboot of application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications

 

 

LINE / BATTERY TRANSFER

Transfer time from line power to battery mode

2-4 milliseconds

Low voltage transfer

Switches to battery power as line voltage drops to 83V or lower / Resets to AC mode as line voltage increases to 87V

to battery power

or higher

 

 

High voltage transfer

Switches to battery power as line voltage increases to 147V or higher / Resets to line power as line voltage drops to

to battery power

143V or less

 

 

SPECIAL FEATURES

 

Cold Start

Yes, inverter can be "cold started" to enable temporary AC output during a power failure

 

 

CERTIFICATIONS

 

Certifications

Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), NOM (Mexico), Class B (Emissions), FCC Part 68 and

 

Industry Canada (Telecommunications)

 

 

WARRANTY

 

Image 3