Tripp Lite SU6K manual RS-232 Interface, AS-400 Interface, Hardware, Pin assienment, Pin assimment

Page 13

RS-232 INTERFACE

This female DB9 port connects your UPS via an RS-232 cable to a workstation or server equipped with Tripp Lite software. The port uses RS-232 communications to report UPS status and power conditions. Using this port, M p p Lite software can monitor and manage network power and automatically save open files and shut down equipment during a blackout. Contact M p p Lite Customer Support at (773)869-1233 for informa- tion on available SNMP, network management and connectivity software and products.

RS-232 signals and operations include: load level, battery status, battery level. operation mode, AC input voltage, AC output voltage, AC input frequency. temperature inside unit, set shut-down delay time, enable/disable alarm and remote shutdown.

Hardware:

Baud Rate:

2400 BPS

Pin assienment;

Data Length:

8 bits

Pin 2:

TXD (Transmit Data)

Stop Bit:

1 bit

Pin 3:

RXD (ReceivingData)

Parity:

NONE

Pin 5:

GND (Signal Ground)

AS-400 INTERFACE:

This female DB9 port connects your UPS to an IBM AS-400 computer via the included AS-400 cable.The port uses AS-400 communications to report UPS status. It can be used to allow an AS-400 to automatically save open files and shut down its operating system during a blackout. AS-400 protocol includes: operation on inverter, operation on AC power supply, operation on battery and low battery alarm.

pin assimment:

Pin 5:

Common

Pin 6:

Operation on AC power supply

Pin 7:

Low battery alarm

Pin 8:

Operation on inverter

Pin 9:

Operation on battery

LOW BATTERY

INVERTER

E l

I

1941 I

AS-400INTERFACE TABLE

 

 

 

 

Pin 6,5

Pin 7.5

Pin 8.5

Pin 9,5

Battery

OFF

 

ON

ON

Low Battery

OFF

ON

ON

ON

Direct Mains Supply

ON

OFF

OFF

OFF

Inverter

OFF

*

ON

*

*Inactive:may be in either state.

13

Image 13
Contents TRIPPaUTEPOWER PRorEcTloN UPS Location Warnings Battery WarningsUPS Connection Warnings Equipment Connection WarningsUPS System Front PanelSubp Rear Panels Overational Mode Selection Inverter Operationdip Switch Settings Suiokpm ShownInDut Voltage Selection Invut Frequencv SelectionInputand Output Connection UPS LocationCable Connection for 6kVA or lOkVA Output 6kVAshown SUBPSUlOKBPSUlOKPM External Battery Pack ConnectionInitial Bavery Charging Optional BA77ERY Condition VerificationTurning the UPS on Turning the UPS OFFSltll~lOlllll~ SELF-TESTINGOperation on BYPASS-VOLTAGE OUT of Range LCD Display Select SwitchOperation on Overload Batery Charge WARNlNGS Operation of Manual Bypass SwitchOperationundershutdown AS-400 Interface RS-232 InterfaceHardware Pin assienmentDRY Contact Interface Remote Emergency Power OFFPin assipnment Pin assignment lSU6K ShownService DLs SU6K