Tripp Lite SU8000RT3U1TF warranty Features, Specifications, System Overview, Output, Input

Page 2

Package Includes

3U power module with detachable hot-swap PDU input/output panel and bypass switch

3U external battery pack, 2U step-down transformer

Three sets of 4 post rackmount rails (one for each of the 2U and 3U components)

One set of tower stands for upright tower configuration

PowerAlert software, complete data cabling, user manual with warranty information

Features

8,000 VA (8kVA) on-line, double-conversion UPS system (High voltage input/High AND low voltage output)

Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without powering off connected equipment

Installs in only 8 rack spaces (3U power module/3U battery pack/2U step-down transformer) with a maximum installed depth of 32.5 inches Offers 6 min. runtime at full load (8000VA/6400W) and 15 min. at half load (4000VA/3200W). Runtime is expandable with any number of optional external battery packs

Full-time sine wave 208V and simultaneous 120V +/-2% output

Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output

Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V

Standard 3-wire 208V hardwire input connection

2 x NEMA L6-30R, 4 x L6-20R and 12 x 5-15/20R output receptacles

Detailed LCD panel with scroll buttons offers detailed diagnostic test

Network-grade AC surge and noise suppression

Zero transfer time between AC and battery operation

Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port, and contact closure port for unattended shudown, remote control and monitoring of UPS system and power data

Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling

Emergency Power Off (EPO) interface

Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC & DC-to-AC conversion, bypass mode and output power status.

Fault-tolerant auto-bypass mode prevents loss of output during UPS fault conditions or excessive UPS loading

4 post rackmount and upright tower installation accessories included. 2POSTRMKITWM two post rackmount hardware accessories available

Field replaceable, hot swappable power module and external battery packs

Attractive all-black color scheme

2-year warranty: $250,000 connected equipment insurance Extended warranty and service contracts available

Specifications

SYSTEM OVERVIEW

Voltage compatibility

208V & 120V AC

 

 

Frequency

50/60 Hz

compatibility

 

 

 

OUTPUT

 

Output VA

8000

 

 

Output watts

6400

 

 

Output nominal

208V & 120V AC

voltage

 

 

 

Output voltage

Maintains pure sine wave output at all times, regulated within 2% of selected nominal output voltage, less than 3% total

regulation

harmonic distortion when used with computer loads

 

 

Output frequency

Regulates line frequency to 50/60Hz +/- 0.05Hz

regulation

 

 

 

Outlet quantity / type

4 NEMA L6-20R, 2 NEMA L6-30R, 12 NEMA 5-15/20R

 

 

INPUT

 

Maximum input amps

208V - 36A

 

 

Image 2
Contents Highlights DescriptionSystem Overview FeaturesSpecifications OutputSurge / Noise Suppression BatteryLeds Alarms & Switches PhysicalRelated Items Rackmount/Wallmount Kits Snmp AccessoriesStart-Up/Warranty Services Shutdown Cable Kits