 RV2012OEM serves as an automotive or stationary 
 Supports 120V AC output from a 120V AC line power source or 12V DC battery source
 16.6 millisecond automatic transfer between line and battery power supports UPS protection during blackouts and voltage fluctuations for equipment compatible with a one cycle transfer time
 2000 watts continuous AC output in inverter mode, 2400 watts continuous AC output in AC mode
 Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds 
 OverPower inverter output supports longer duration overloads to 150% for 
 3 stage, selectable 25/100 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging
 Protected hardwire 
 Protected hardwire output passes 120V line power or inverter output through to connected equipment. Includes optional 
 Reliability enhanced 
 
 3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, 
 Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status 
 Set of 4 configuration dipswitches support wet/gel battery charging profiles, adjustable 135/145V high voltage auto transfer during overvoltages and selectable 75/85/95/105V AC low voltage auto transfer during brownouts
 Set of 4 additional configuration dipswitches support 4 levels of charger limiting relative to output load size, a battery equalization program and battery charger low/high settings
 Resettable 25A charger AC input breaker and resettable dual 20A 
 Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system
 Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
 Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory). Optional APSRM4 accessory also includes user configurable jacks to support inverter shutoff or startup as a vehicle ignition is engaged
 Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load conditions change
 Includes battery temperature sensor with 20 foot cable to prolong battery life by adjusting the charge level based on battery temperature 
 Automatic Generator Starter jack enables user configuration of automatic generator startup as inverter batteries drop to 11.5VDC and generator shutoff as inverter batteries are recharged to 14.1VDC
Specifications
OVERVIEW
Intended  | RV/Marine  | 
Application  | 
  | 
  | 
  | 
SYSTEM OVERVIEW | 
  | 
Voltage  | 12VDC / 120VAC  | 
compatibility  | 
  | 
  | 
  | 
Frequency  | 60 Hz  | 
compatibility  | 
  | 
  | 
  | 
OUTPUT | 
  | 
Output watts  | 2000W (continuous) / 4000W (peak)  | 
  | 
  | 
Output nominal  | 120V  | 
voltage  | 
  | 
  | 
  | 
Output voltage  | LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC):  | 
regulation  | Maintains PWM sine wave output voltage of 120 VAC   | 
  | 
  | 
Output frequency  | 60 Hz (+/- 0.3 Hz)  | 
regulation  | 
  | 
  | 
  | 
Outlet quantity /  | Hardwire  | 
type  | 
  | 
  | 
  | 
Overload  | Includes 25A input breaker dedicated to the charging system and 2 branch rated 20A output load breakers  | 
protection  | 
  | 
  | 
  |