Specifications
MODEL NUMBER: | RV612UL | RV612ULH | RV1012UL | RV1012ULH | RV1512 | RV1512OEM | RV2012OEM | RV2012UL | RV2512OEM | RV3012OEM |
Series Number: | AGAP60012MVJ | AGAP60012MVJ | AGAP100012MV3 | AGAP100012MV3 | AGAP200012MV3 | AGAP200012MVP3 | AGAP200012MVP3 | AGAP200012MV3 | | |
AC Input Connection: | Input Cord | Hardwire | Input Cord | Hardwire | Hardwire | Hardwire | Hardwire | Hardwire | Hardwire | Hardwire |
INVERTER
Common Specifications for All Models: • DC Input Volts (Nominal):12 VDC • · DC Input Voltage Range:10 - 15 VDC • Output Volts (Nominal):120 VAC, ± 5% • Output Frequency (Nominal):60 Hz, ± 0.5% • Efficiency:88% to 94%, depending on load and temperature
Select Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s inverter turns on. Users can significantly reduce the No Load DC Input Current (approximately 2.5 to 4 A for all models) to a very low amp level with the use of this control.
| Continuous Power (@ 20 C): | 600 | 600 | 1000 | 1000 | 1500 | 1500 | 2000 | 2000 | 2500 | 3000 |
| OverPower™ Peak Surge Power:* | 900 | 900 | 1500 | 1500 | 2250 | 2250 | 3000 | 3000 | 3750 | 4500 |
| Double Boost™ Peak Surge Power:* | 1200 | 1200 | 2000 | 2000 | 3000 | 3000 | 4000 | 4000 | 5000 | 6000 |
| Maximum Output AC Current | 5 A | 5 A | 8.3 A | 8.3 A | 12.5 A | 12.5 A | 16.7 A | 16.7 A | 20 A | 25 A |
| (Continuous): | | | | | | | | | | |
| UL Required DC Fuse | TPN-80 (fuse) | TPN-80 (fuse) | ANL-200 (fuse) | ANL-200 (fuse) | ANL-275 | two ANL-200 (fuses) | two ANL-200 (fuses) | ANL-325 (fuse) | two ANL-200 (fuses) | two ANL-275 (fuses) |
| and Fuse Block: | R25100-1CR (fuse block) | R25100-1CR (fuse block) | 1DK98 (fuse block) | 1DK98 (fuse block) | 1DK98 (fuse block) | two 1DK98 (fuse blocks) | two 1DK98 (fuse blocks) | 1DK98 (fuse block) | two 1DK98 (fuse blocks) | two 1DK98 (fuse blocks) |
| | Bussmann | Bussmann | Bussmann | Busmann | Bussmann | Bussmann | Bussmann | Bussmann | Bussmann | Bussmann |
| | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) | (manufacturer) |
| DC Input Current @ | | | | | | | | | | |
| Nominal V DC Full Load: | 56A | 56A | 95A | 95A | 143 A | 143 A | 192A | 190A | 240 A | 290A |
| | | | | | | | | | | |
| BATTERY CHARGER | | | | | | | | | | |
| | | | | | | | | | | |
| Common Specifications for All Models • Acceptance Volts VDC:Selectable 14.4 V** / 14.2 V Wet** / Gel • Float Volts DC (w/gel):13.3 V (13.6 V) • · Input Volts (Nominal):120 VAC | | | | |
| Charging Capacity DC: | 45 A / 11 A** | 45 A / 11 A** | 55 A / 14 A** | 55 A / 14 A** | 80 A / 20 A** | 80 A / 20 A** | 100 A / 25 A** | 100 A / 25 A** | 120 A / 30 A** | 140 A / 35 A** |
| Input Current AC: | 9.5 A | 9.5 A | 11.5 A | 11.5 A | 16.7 A | 16.7 A | 20 A | 20 A | 24 A | 30 A |
| | | | | | | | | | | |
| LINE VAC OPERATION | | | | | | | | | | |
| | | | | | | | | | | |
| Common Specifications for All Models • Input Frequency (Nominal):60 Hz, ±10% • Maximum Input Volts (Transfer to Battery) (Continuous, Charger at Maximum):Selectable 135** or 145 VAC | | | | |
| Minimum Input Volts: | Selectable 95** or | Selectable 95** or | Selectable 75**, 85, | Selectable 75**, 85, | Selectable 75**, 85, | Selectable 75**, 85, | Selectable 75**, 85, | Selectable 75**, 85, | Selectable 75**, 85, | Selectable 75**, 85, |
| (Transfer to Battery) | 105 VAC | 105 VAC | 95 or 105 VAC | 95 or 105 VAC | 95 or 105 VAC | 95 or 105 VAC | 95 or 105 VAC | 95 or 105 VAC | 95 or 105 VAC | 95 or 105 VAC |
| Maximum Input AC Current | 11.3 A | 14.5 A | 12.1 A | 20 A | 29 A | 29 A | 38 A | 38 A | 44 A | 56 A |
| (Continuous, Charger | | | | | | | | | | |
| at Maximum): | | | | | | | | | | |
| Maximum Bypass AC Current: | 6 A | 6A | 12 A | 12 A | 20 A | 15/20 A | 15/20 A | 20 A | 20/20 A | 20/20 A |
| (Load circuit breaker limited) | | | | | | | | | | |
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Limited Warranty
Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a 30 month period from the date of retail purchase by end user.
Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an author- ized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of retail purchase.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.