Moxa Technologies 405A SERIES, EDS-408A user manual Email Settings, Port Event

Page 61

 

EDS-408A/405A Series User’s Manual

 

Featured Functions

 

 

 

 

 

 

 

 

 

 

 

 

Port Event

 

Warning e-mail is sent when…

 

 

 

 

 

Link-on

The port is connected to another device.

 

 

 

 

 

Link-off

 

The port is disconnected (e.g., the cable is pulled

 

 

 

 

 

 

out, or the opposing device shuts down).

 

 

 

 

 

 

 

 

 

 

 

 

Traffic-Overload

 

The port’s traffic surpasses the Traffic-Threshold for

 

 

 

 

 

 

that port (provided this setting is Enabled).

 

 

 

 

 

 

 

 

 

 

 

 

Traffic-Threshold (%)

 

Enter a nonzero number if the port’s

 

 

 

 

 

 

Traffic-Overload setting is Enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A Traffic-Overload warning is sent every

 

 

 

 

 

Traffic-Duration (sec.)

 

Traffic-Durationseconds if the average

 

 

 

 

 

 

Traffic-Threshold is surpassed during that time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

period.

 

 

 

 

 

 

 

 

 

 

 

NOTE

The Traffic-Overload,Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event settings

 

 

are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero

 

 

Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.

 

 

 

 

 

 

 

NOTE

Warning e-mail messages will have the sender field in the form:

 

 

 

 

Moxa_EtherDevice_Switch_0001@Switch_Location

 

 

where Moxa_EtherDevice_Switch is the default Switch Name, 0001 is EDS’s serial number, and

 

 

Switch_Location is the default Server Location.

 

 

Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.

 

 

 

 

 

 

 

 

Email Settings

3-46

Image 61
Contents Second Edition, July Moxa EtherDevice Switch EDS-408A/405A Series User’s ManualTrademarks Copyright NoticeDisclaimer Table of Contents Chapter EDS Configurator GUI Introduction Package Checklist Moxa EtherDevice SwitchInside the Future of Industrial Ethernet Technology Industrial vs. CommercialFeatures Optional AccessoriesUseful Utility and Remote Configuration Advanced Industrial Networking CapabilityGetting Started Connection Caution RS-232 Console Configuration 115200, None, 8, 1, VT100EDS-408A/405A Series User’s Manual Key Function Configuration Using a Telnet Console Configuration Using a Web Browser EDS-408A/405A Series User’s Manual Configuration Disabling Telnet and Browser AccessFeatured Functions System Identification Configuring Basic SettingsPassword PasswordAccount Any host can access the EDS-408A/405A Accessible IPAllowable Hosts Input format Port EnableName Port Transmission Speed NetworkFDX Flow Control Port TypeSwitch IP Address Auto IP ConfigurationSwitch Subnet Mask Default GatewayDaylight Saving Time TimeCurrent Time Current DateTurbo Ring DIP Switch Disable the Turbo Ring DIP Switch How to Enable or Disable the Turbo Ring DIP SwitchesSet DIP switch as Turbo Ring / Set DIP switch as Turbo Ring Redundancy Protocol drop-down box. See the Configuring How to Configure the Turbo Ring DIP SwitchesTurbo Ring and Turbo Ring V2 section in this chapter for System File Update-By Remote Tftp System File Update-By Local Import/Export Factory Default System File Update-By Backup MediaRestart Snmp Configuring SnmpSnmp Versions Snmp Read/Write SettingsV1, V2c Read Community V1, V2c Write/Read CommunityTrap Server IP/Name Setting Description Factory Default Setting Description Factory DefaultTurbo Ring Concept Using Communication RedundancyInitial setup of a Turbo Ring or Turbo Ring V2 ring Determining the Redundant Path of a Turbo Ring V2 Ring Ring Coupling ConfigurationRing Coupling for a Turbo Ring Ring Dual-Homing Configuration applies only to Turbo Ring Dual-Ring Configuration applies only to Turbo RingConfiguring Turbo Ring Configuring Turbo Ring and Turbo RingNow Active Master/SlaveRedundancy Protocol Enable Ring CouplingSet as Master Redundant PortsRing 1/2-Master/Slave Ring 1/2-StatusRing 1/2-1st Ring Port Status Ring 1/2-2nd Ring Port StatuCoupling-Mode Enable RingIndicates either None, Dual Homing, or Ring Coupling Coupling-Coupling Port statusPrimary/Backup Port Coupling ModeSTP/RSTP Concept What is STP? STP Requirements How STP WorksSTP Reconfiguration STP ConfigurationDifferences between Rstp and STP Port Speed Path Cost 802.1D Edition 802.1w-2001STP Example Using STP on a Network with Multiple VLANsConfiguring STP/RSTP Root/Not Root Forwarding DelayProtocol of Redundancy Bridge priorityConfiguration Limits of RSTP/STP What is Traffic Prioritization? Using Traffic PrioritizationTraffic Prioritization Concept How Traffic Prioritization WorksIeee 802.1p Priority Level Ieee 802.1D Traffic Type Differentiated Services DiffServ Traffic MarkingTraffic Prioritization Traffic Queues QoS Classification Configuring Traffic PrioritizationQueuing Mechanism Inspect TOSInspect COS Default Port PriorityCoS Mapping What is a VLAN? Using Virtual LANsVirtual LAN Vlan Concept TOS/DiffServ MappingPort-based VLANs and the Moxa EtherDevice Switch Using Virtual LANsBenefits of VLANs Settings-Turbo Ring DIP Switch Configuring Rate Limiting Using Rate LimitingPolicy Configuring Email Warning Using Auto WarningConfiguring Email Settings Email Warning Events SettingsActivate your settings and test email if necessary Event TypesMoxaEtherDeviceSwitch0001@SwitchLocation Email SettingsPort Event Configuring Relay Warning Activate your settings Relay Warning Events SettingsOverride Relay Warning Settings Using Line-Swap-Fast-RecoveryRelay Warning List Configuring Line-Swap Fast Recovery Using Set Device IPEnable Line-Swap-Fast-Recovery Configuring Set Device IP Using DiagnosisMirror Port Desired IP AddressInput data stream PingOutput data stream Bi-directionalMonitor by Switch Using the MonitorMonitor by Port ALL Using the MAC Address TableUsing Syslog Using Event LogSyslog Server EDS Configurator GUI Broadcast Search Starting EDS ConfiguratorSearch by IP address Upgrade FirmwareModify IP Address Export Configuration Import Configuration Unlock Server EDS-408A/405A Series User’s Manual MIB II.16 Rmon MIB GroupsPower SpecificationsTechnology InterfaceEnvironment MechanicalRegulatory Approvals Service Information Following services are provided Moxa Internet ServicesMoxa Products Problem Report FormSerial Number Product Return Procedure
Related manuals
Manual 82 pages 15.35 Kb

405A SERIES, EDS-408A specifications

Moxa Technologies has established itself as a leader in networking solutions, particularly for industrial applications. Among their cutting-edge products is the 405A Series, specifically the EDS-408A model, which exemplifies Moxa's commitment to performance, reliability, and versatility in industrial Ethernet switches.

The EDS-408A is an 8-port industrial Ethernet switch that offers an impressive array of features and capabilities designed to meet the demands of harsh environments. One of its main highlights is the ability to support both 10/100 Mbps Fast Ethernet and Gigabit Ethernet connections, providing users with the flexibility to integrate a range of devices within their network. Its robust design ensures that it operates seamlessly in extreme conditions, with a wide operating temperature range from -40 to 75 degrees Celsius.

The EDS-408A is built to support an array of networking topologies. It features advanced Ethernet switching technologies that enable fast and efficient data transfer while minimizing latency. The device is equipped with wire-speed forwarding capabilities, which is vital for maintaining high performance in heavy network traffic scenarios.

Another key feature of the EDS-408A is its redundancy support. The switch incorporates various redundancy protocols, including Rapid Spanning Tree Protocol (RSTP) and MRP (Media Redundancy Protocol), which enhance network reliability by allowing quick recovery in the event of a failure. This ensures continuous network uptime, which is critical for industrial applications.

Furthermore, Moxa Technologies has adopted an user-friendly web-based management interface in the EDS-408A, simplifying the configuration and monitoring process. This allows system administrators to easily manage settings, monitor traffic, and troubleshoot issues in real time. Additionally, the switch supports SNMP (Simple Network Management Protocol) for remote monitoring and management, enabling organizations to keep their networks optimized.

Security is another paramount feature of the EDS-408A. It includes built-in security mechanisms such as port security, VLAN, and access control lists (ACLs), which help safeguard sensitive network segments from unauthorized access.

In conclusion, Moxa Technologies' EDS-408A model from the 405A Series is a robust and feature-rich industrial Ethernet switch designed for demanding environments. With its support for various network protocols, redundancy features, user-friendly management, and enhanced security, the EDS-408A stands out as a reliable solution for organizations looking to enhance their industrial networking capabilities.