Moxa Technologies 405A SERIES, EDS-408A Syslog Server, Setting Description Factory Default

Page 71

EDS-408A/405A Series User’s Manual

Featured Functions

Syslog Server 1

 

 

Setting

Description

Factory Default

IP Address

Enter the IP address of 1st Syslog Server used by your

None

 

network.

 

Port Destination

Enter the UDP port of 1st Syslog Server.

514

(1 to 65535)

 

 

Syslog Server 2

 

 

Setting

Description

Factory Default

IP Address

Enter the IP address of 2nd Syslog Server used by your

None

 

network.

 

Port Destination

Enter the UDP port of 2nd Syslog Server.

514

(1 to 65535)

 

 

 

Syslog Server 3

 

 

 

 

 

Setting

 

Description

Factory Default

 

 

IP Address

 

Enter the IP address of 3rd Syslog Server used by your

None

 

 

 

 

 

network.

 

 

 

Port Destination

 

Enter the UDP port of 3rd Syslog Server.

514

 

 

(1 to 65535)

 

 

 

 

 

 

 

NOTE

The following events will be recorded into the EDS-408A/405A’s Event Log table, and will then

 

 

be sent to the specified Syslog Server:

 

 

 

1.

Cold start

 

 

 

 

2.

Warm start

 

 

 

 

3.

Configuration change activated

 

 

 

4.

Power 1/2 transition (Off Æ On), Power 1/2 transition (On Æ Off)

 

 

 

5.

Authentication fail

 

 

 

6.

Topology changed

 

 

 

7.

Master setting is mismatched

 

 

 

8.

DI 1/2 transition (Off Æ On), DI 1/2 transition (On Æ Off)

 

 

 

9.

Port traffic overload

 

 

 

10.

dot1x Auth Fail

 

 

 

 

11.

Port link off / on

 

 

 

 

 

 

 

 

 

3-56

Image 71
Contents Second Edition, July Moxa EtherDevice Switch EDS-408A/405A Series User’s ManualDisclaimer Copyright NoticeTrademarks Table of Contents Chapter EDS Configurator GUI Introduction Industrial vs. Commercial Moxa EtherDevice SwitchPackage Checklist Inside the Future of Industrial Ethernet TechnologyAdvanced Industrial Networking Capability Optional AccessoriesFeatures Useful Utility and Remote ConfigurationGetting Started Connection Caution RS-232 Console Configuration 115200, None, 8, 1, VT100EDS-408A/405A Series User’s Manual Key Function Configuration Using a Telnet Console Configuration Using a Web Browser EDS-408A/405A Series User’s Manual Configuration Disabling Telnet and Browser AccessFeatured Functions System Identification Configuring Basic SettingsAccount PasswordPassword Allowable Hosts Input format Accessible IPAny host can access the EDS-408A/405A Name EnablePort Port Type NetworkPort Transmission Speed FDX Flow ControlDefault Gateway Auto IP ConfigurationSwitch IP Address Switch Subnet MaskCurrent Date TimeDaylight Saving Time Current TimeTurbo Ring DIP Switch Set DIP switch as Turbo Ring / Set DIP switch as Turbo Ring How to Enable or Disable the Turbo Ring DIP SwitchesDisable the Turbo Ring DIP Switch Turbo Ring and Turbo Ring V2 section in this chapter for How to Configure the Turbo Ring DIP SwitchesRedundancy Protocol drop-down box. See the Configuring System File Update-By Remote Tftp System File Update-By Local Import/Export Restart System File Update-By Backup MediaFactory Default Snmp Configuring SnmpV1, V2c Write/Read Community Snmp Read/Write SettingsSnmp Versions V1, V2c Read CommunityTrap Server IP/Name Setting Description Factory Default Setting Description Factory DefaultTurbo Ring Concept Using Communication RedundancyInitial setup of a Turbo Ring or Turbo Ring V2 ring Determining the Redundant Path of a Turbo Ring V2 Ring Ring Coupling ConfigurationRing Coupling for a Turbo Ring Ring Dual-Homing Configuration applies only to Turbo Ring Dual-Ring Configuration applies only to Turbo RingMaster/Slave Configuring Turbo Ring and Turbo RingConfiguring Turbo Ring Now ActiveRedundant Ports Enable Ring CouplingRedundancy Protocol Set as MasterRing 1/2-2nd Ring Port Statu Ring 1/2-StatusRing 1/2-Master/Slave Ring 1/2-1st Ring Port StatusCoupling-Coupling Port status Enable RingCoupling-Mode Indicates either None, Dual Homing, or Ring CouplingSTP/RSTP Concept Coupling ModePrimary/Backup Port What is STP? STP Requirements How STP WorksPort Speed Path Cost 802.1D Edition 802.1w-2001 STP ConfigurationSTP Reconfiguration Differences between Rstp and STPSTP Example Using STP on a Network with Multiple VLANsConfiguring STP/RSTP Bridge priority Forwarding DelayRoot/Not Root Protocol of RedundancyConfiguration Limits of RSTP/STP How Traffic Prioritization Works Using Traffic PrioritizationWhat is Traffic Prioritization? Traffic Prioritization ConceptTraffic Prioritization Differentiated Services DiffServ Traffic MarkingIeee 802.1p Priority Level Ieee 802.1D Traffic Type Traffic Queues Inspect TOS Configuring Traffic PrioritizationQoS Classification Queuing MechanismCoS Mapping Default Port PriorityInspect COS TOS/DiffServ Mapping Using Virtual LANsWhat is a VLAN? Virtual LAN Vlan ConceptBenefits of VLANs Using Virtual LANsPort-based VLANs and the Moxa EtherDevice Switch Settings-Turbo Ring DIP Switch Policy Using Rate LimitingConfiguring Rate Limiting Configuring Email Warning Using Auto WarningEvent Types Email Warning Events SettingsConfiguring Email Settings Activate your settings and test email if necessaryPort Event Email SettingsMoxaEtherDeviceSwitch0001@SwitchLocation Configuring Relay Warning Activate your settings Relay Warning Events SettingsRelay Warning List Using Line-Swap-Fast-RecoveryOverride Relay Warning Settings Enable Line-Swap-Fast-Recovery Using Set Device IPConfiguring Line-Swap Fast Recovery Desired IP Address Using DiagnosisConfiguring Set Device IP Mirror PortBi-directional PingInput data stream Output data streamMonitor by Port Using the MonitorMonitor by Switch ALL Using the MAC Address TableUsing Syslog Using Event LogSyslog Server EDS Configurator GUI Broadcast Search Starting EDS ConfiguratorSearch by IP address Upgrade FirmwareModify IP Address Export Configuration Import Configuration Unlock Server EDS-408A/405A Series User’s Manual MIB II.16 Rmon MIB GroupsInterface SpecificationsPower TechnologyRegulatory Approvals MechanicalEnvironment Service Information Following services are provided Moxa Internet ServicesSerial Number Problem Report FormMoxa Products Product Return Procedure
Related manuals
Manual 82 pages 15.35 Kb

405A SERIES, EDS-408A specifications

Moxa Technologies has established itself as a leader in networking solutions, particularly for industrial applications. Among their cutting-edge products is the 405A Series, specifically the EDS-408A model, which exemplifies Moxa's commitment to performance, reliability, and versatility in industrial Ethernet switches.

The EDS-408A is an 8-port industrial Ethernet switch that offers an impressive array of features and capabilities designed to meet the demands of harsh environments. One of its main highlights is the ability to support both 10/100 Mbps Fast Ethernet and Gigabit Ethernet connections, providing users with the flexibility to integrate a range of devices within their network. Its robust design ensures that it operates seamlessly in extreme conditions, with a wide operating temperature range from -40 to 75 degrees Celsius.

The EDS-408A is built to support an array of networking topologies. It features advanced Ethernet switching technologies that enable fast and efficient data transfer while minimizing latency. The device is equipped with wire-speed forwarding capabilities, which is vital for maintaining high performance in heavy network traffic scenarios.

Another key feature of the EDS-408A is its redundancy support. The switch incorporates various redundancy protocols, including Rapid Spanning Tree Protocol (RSTP) and MRP (Media Redundancy Protocol), which enhance network reliability by allowing quick recovery in the event of a failure. This ensures continuous network uptime, which is critical for industrial applications.

Furthermore, Moxa Technologies has adopted an user-friendly web-based management interface in the EDS-408A, simplifying the configuration and monitoring process. This allows system administrators to easily manage settings, monitor traffic, and troubleshoot issues in real time. Additionally, the switch supports SNMP (Simple Network Management Protocol) for remote monitoring and management, enabling organizations to keep their networks optimized.

Security is another paramount feature of the EDS-408A. It includes built-in security mechanisms such as port security, VLAN, and access control lists (ACLs), which help safeguard sensitive network segments from unauthorized access.

In conclusion, Moxa Technologies' EDS-408A model from the 405A Series is a robust and feature-rich industrial Ethernet switch designed for demanding environments. With its support for various network protocols, redundancy features, user-friendly management, and enhanced security, the EDS-408A stands out as a reliable solution for organizations looking to enhance their industrial networking capabilities.