| 24 |
|
|
|
Double OSD | Improper slave | Press push buttons 1 and 2 |
images at | connection procedure. | down for 2 seconds to activate |
cascade |
| K/M RESET. |
configuration |
| Remove any possible power |
|
| supply to the Slave (unplug all |
|
| cables), before connecting it to |
|
| the Master. |
OSD menu is | OSD menu has fixed | Use <F4>: More\Position to |
not at the | resolution and its size | select UL or UR. OSD menu |
proper position | varies due to computer | may appear near the middle of |
| VGA resolution changes. | the screen when LL or LR is |
|
| selected. |
Computer can | Loose mouse adapter | Secure the mouse adapter to |
not use serial |
| computer’s COM port |
mouse | Incorrect mouse adapter | Use only the mouse adapter |
|
| comes with the unit |
Can not select a | Improper Master unit | Only Master ports PC1~PC8 |
computer | connection | can be connected to slaves. |
connected to a | Improper slave unit | Connect slave CONSOLE port |
slave | connection | to PC1~PC8 ports of the Master |
| Too many levels of | Only one level of slave units is |
| slaves | allowed. Pop up OSD again to |
|
| check if Master recognizes the |
|
| slave connection. Look for |
|
| triangle mark and the number |
|
| before it. |
The StarView | Computers do not supply | Make sure a power adapter with |
fails to function | enough power. | minimum of 9V |
occasionally. |
| rating is firmly connected to the |
|
| power jack. |