Q-Logic 59244-00 A Disconnect Ethernet and Serial Cables, Disconnect Fibre Channel Port Cables

Page 3

A

SANbox 9000Series Chassis Replacement Guide

Disconnect Ethernet and Serial Cables

Disconnect Ethernet cables from CPU blades and the Maintenance Panel.

Disconnect HyperStacking cables from the CPU blades.

Disconnect Fibre Channel Port Cables

Label I/O blades by slot number. I/O blade slots are numbered IO0–IO7.

Label Fibre Channel port cables by slot number and port number.

„4-Gbps I/O blade ports are numbered 0–15 from top to bottom, left to right.

„10-Gbps I/O blade ports are numbered 0–4, top to bottom, left to right.

Disconnect Fibre Channel port cables.

 

IO0

IO1

0

8

 

7

15

 

Remove I/O Blades

Connect an ESD wrist strap to a ground point on the rack.

Rotate the I/O blade latch to the full open position. Pull the I/O blade by the latch to disengage the I/O blade from the midplane. Carefully slide the I/O blade out of the chassis.

Remove I/O blade panels in the same way.

1

1. Latch, IO0 blade

59244-00 A

3

Image 3
Contents Tools Required SANbox 9000 Series Chassis Replacement GuideBackup the Switch Configuration Inventory Feature LicensesPower Down the Switch Disconnect Ethernet and Serial Cables Disconnect Fibre Channel Port CablesRemove I/O Blades Remove Power Supply Blades Remove the Fan BladesRemove CPU Blades Remove Chassis from the Rack Remove Brackets and RailsPrepare the New Chassis Install New Chassis Rack Reinstall CPU BladesReinstall Fan Blades Reconnect Ethernet and Serial Cables Reinstall Power Supply BladesReinstall I/O Blades Power Up the SwitchReinstall License Keys Observe Heartbeat LEDVerify the Post Results