A

Observe Heartbeat LED

Observe the Heartbeat LED on the CPU blade. It should blink once per second.

If the Heartbeat LED is showing a different blink pattern, refer to the Installation Guide for diagnostic procedures or contact your authorized maintenance provider.

1

1. Heartbeat LED

Verify the POST Results

Open a Telnet session and enter the Show Blade command to display the diagnostic status for all blades. You can also use the Switch tab and Blade Info tab of the QuickTools interface.

telnet 10.0.0.1

 

 

 

 

 

 

Switch Login: admin

 

 

 

 

 

Password: password

 

 

 

 

 

SANbox #>show blade

 

 

 

 

 

Blade

Blade

Port

Admin

Oper

Fault

Temp

Voltage

ID

Type

Range

State

State

Status

Status

Status

-----

----

-----

-----

-----

------

------

------

IO0

FC4G16

0-15

Online

Online

None

Normal

Good

IO1

FC4G16

16-31

Online

Online

None

Normal

Good

IO2

*

*

Online

NotInst

*

*

*

IO3

*

*

Online

NotInst

*

*

*

IO4

*

*

Online

NotInst

*

*

*

IO5

*

*

Online

NotInst

*

*

*

IO6

*

*

Online

NotInst

*

*

*

IO7

*

*

Online

NotInst

*

*

*

+CPU0

CPU

N/A

Online

Online

None

Normal

Good

CPU1

CPU

N/A

Online

Online

None

Normal

Good

PS0

PSFB

N/A

N/A

N/A

None

N/A

N/A

PS1

PSFB

N/A

N/A

N/A

None

N/A

N/A

FAN0

FANFB

N/A

N/A

N/A

None

N/A

N/A

FAN1

FANFB

N/A

N/A

N/A

None

N/A

N/A

MP

MP

N/A

N/A

N/A

None

N/A

N/A

Reinstall License Keys

The old license keys are not valid with the new chassis serial number. Visit www.QLogic.com (Support/Product Feature Activation/

License Key Activation Center/Replace License Keys) to obtain new license keys to replace those installed on the original chassis.

SANbox #> admin start

SANbox (admin) #> feature add #-XXXXXXXXXXXXX License upgradefor HyperStack(tm) capability.

This feature upgrade does NOT require a switch reset. Do you want to continue with license upgrade procedure?

(y/n): [n] y

Log Msg: [day mon date hh:mm:ss.sss CST year] [C][8400.006B][Switch][Upgrading License for HyperStack(tm)capability]

Log Msg: [day mon date hh:mm:ss.sss CST year] [C][8400.0047][Switch][New licenses are being installed]

You will need the following information:

„Original chassis serial number

„New chassis serial number (Show Version command)

„Your email address

With the new license keys, enter the Feature Add command to install license keys that were installed on the original chassis.

Copyright© 2007 QLogic Corporation. SANbox is a trademark of QLogic Corporation

8

59244-00 A

Image 8
Contents SANbox 9000 Series Chassis Replacement Guide Tools RequiredPower Down the Switch Backup the Switch ConfigurationInventory Feature Licenses Remove I/O Blades Disconnect Ethernet and Serial CablesDisconnect Fibre Channel Port Cables Remove CPU Blades Remove Power Supply BladesRemove the Fan Blades Prepare the New Chassis Remove Chassis from the RackRemove Brackets and Rails Reinstall Fan Blades Install New Chassis RackReinstall CPU Blades Reinstall Power Supply Blades Reinstall I/O BladesPower Up the Switch Reconnect Ethernet and Serial CablesVerify the Post Results Reinstall License KeysObserve Heartbeat LED