Pelco ips-rdpe-2 manual Mounting Instructions, Wall Mounting

Page 6

Mounting Instructions

WALL MOUNTING

1.Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.91 cm) conduit fittings (not supplied). Close the lid of the IPS-RDPE-2 box.

2.Determine the mounting location for the IPS-RDPE-2.

3.Use the IPS-RDPE-2 box as a template and mark the four fastener positions on the mounting surface.

4.Prepare the holes for installation.

5.Attach the IPS-RDPE-2 securely with four fasteners of appropriate length. Fasteners between 1/4-inch and 5/16-inch diameter can be used (not supplied). Refer to Figure 1.

MOUNTING HARDWARE WITH ANCHOR OR TOGGLE BOLT (NOT SUPPLIED)

DOOR

LATCH

RETAINING

SCREW

CONDUIT

FITTINGS

WALLBOARD

Mounting to Wallboard

WOOD SCREW (NOT SUPPLIED)

DOOR

LATCH

RETAINING

SCREW

CONDUIT

FITTINGS

WALL

Mounting to Wall

Figure 1. Mounting to Different Wall Types

MOUNTING

HARDWARE (NOT SUPPLIED)

DOOR

LATCH

RETAINING

SCREW

CONDUIT

FITTINGS

CONCRETE WALL

Mounting to Concrete

6.Run conduit with wiring from the positioning system to the IPS-RDPE-2. To connect the wires to the IPS-RDPE-2, refer to Figure 3 or to the label attached to the inside lid of the data port box, and do the following:

a.Connect the communication wires from the positioning system to the communication connector of the IPS-RDPE-2.

NOTE: Connect all four communication wires from the Spectra dome system or ExSite system to the IPS-RDPE-2. Transmission and receive wires must be connected to perform software and language file uploads.

b.Connect the power wires from the positioning system to the 24 VAC OUT positions on the power connector of the IPS-RDPE-2. NOTE: If preferred, separate power supplies can be used for the IPS-RDPE-2 and the positioning system.

c.Connect the video wires/cable from the positioning system to either the BNC VIDEO IN connector (if using coaxial) or UTP VIDEO IN connector (if using UTP) of the IPS-RDPE-2.

7.Run conduit with wiring from the power supply and wiring from the controller at the head-end to the IPS-RDPE-2. To connect the wires to the IPS-RDPE-2, refer to Figure 3 or to the label attached to the inside lid of the data port box, and do the following:

WARNING: Turn off power to the power supply before wiring the power to the IPS-RDPE-2.

a.Connect the power wires from the power supply to the 24 VAC IN positions on the power connector of the IPS-RDPE-2.

b.Connect the wires/cable from the controller at the head-end to either the FROM CONTROLLER connector (D or P control), BNC VIDEO OUT connector (Coaxitron control), or UTP VIDEO OUT connector (UTP control) of the IPS-RDPE-2.

6

C2473M-D (10/06)

Image 6
Contents IPS-RDPE-2 Remote Data Port Page Contents List of IllustrationsImportant Safety Instructions Required Accessories DescriptionMounting Instructions Wall MountingPole Mounting Cable/Wire Requirements and Connector Locations Refer to for a layout of the data port box connectorsWiring Diagrams Positioning System IPS-RDP PTZ Control Software Upload Positioning System Software Upload Positioning System UTP Receiver Control System AT Control System VC-UTP RX- RX+ TX- TX+ UTP- UTP+ VAC+ Operation Upload IconSpecifications ElectricalProduct Warranty and Return Information ISO9001