Sun Microsystems X4440, X4240, X4140 manual PCI Serr

Page 76

TABLE D-1

Hardware Error Handling Summary

(Continued)

 

 

 

 

 

 

 

 

 

Logged (DMI

 

 

 

 

Log or SP

 

Error

Description

Handling

SEL)

Fatal?

 

 

 

 

 

PCI SERR,

System or parity

PERR

error on a PCI bus.

BIOS POST

The BIOS could not

Microcode

find or load the

Error

CPU Microcode

 

Update to the CPU.

 

The message most

 

likely appears when

 

a new CPU is

 

installed in a

 

motherboard with

 

an outdated BIOS.

 

In this case, the

 

BIOS must be

 

updated.

Sync floods on HyperTransport links, the

DMI Log

Fatal

machine resets itself, and error information

SP SEL

 

gets retained through reset.

 

 

The BIOS reports, A Hyper Transport

 

 

sync flood error occurred on last

 

 

boot, press F1 to continue.

 

 

The BIOS displays an error message, logs the

DMI Log

Non-fatal

error to DMI, and boots.

 

 

BIOS POST

CMOS contents

The BIOS displays an error message, logs the

DMI Log

Non-fatal

CMOS

failed the

error to DMI, and boots.

 

 

Checksum Bad

Checksum check.

 

 

 

Unsupported

The BIOS supports

The BIOS displays an error message, logs the

DMI Log

Fatal

CPU

mismatched

error, and halts the system.

 

 

configuration

frequency and

 

 

 

 

steppings in CPU

 

 

 

 

configuration, but

 

 

 

 

some CPUs might

 

 

 

 

not be supported.

 

 

 

Correctable

The CPU detects a

The CPU corrects the error in hardware. No

DMI Log

Normal

error

variety of

interrupt or machine check is generated by

SP SEL

operation

 

correctable errors in

the hardware. The polling is triggered every

 

 

 

the MCi_STATUS

half second by SMI timer interrupts, and is

 

 

 

registers.

done by the BIOS SMI handler.

 

 

 

 

The SMI handler logs a message to the SP

 

 

 

 

SEL if the SEL is available, otherwise SMI

 

 

 

 

logs a message to DMI. The BIOS's polling

 

 

 

 

can be disabled through software SMI.

 

 

Single fan

Fan failure is

The Front Fan Fault, Service Action Required,

SP SEL

Non-fatal

failure

detected by reading

and individual fan module LEDs are lit.

 

 

 

tach signals.

 

 

 

 

 

 

 

 

66 Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide • August 2008

Image 76
Contents Sun Fire X4140, X4240, Servers Diagnostics Guide Please Recycle Contents Error Handling Status Indicator LEDsEvent Logs and Post Codes Index Page Preface Before You Read This DocumentRelated Documentation Typographic ConventionsThird-Party Web SitesSun Welcomes Your Comments Service Troubleshooting Flowchart Initial Inspection of the ServerDocument the server settings before you make any changes Gathering Service InformationCollect information about the following items System Inspection Troubleshooting Power ProblemsExternally Inspecting the Server Internally Inspecting the Server 1X4140 Server Front PanelLocate Button/LED Power Button Page Using SunVTS Diagnostic Software Running SunVTS Diagnostic TestsDiagnosing Server Problems With the Bootable Diagnostics CD SunVTS DocumentationUsing the Bootable Diagnostics CD Click the Log button Close the Log file window The window is closedTroubleshooting Dimm Problems Dimm Population RulesHow Dimm Errors Are Handled by the System Dimm Replacement PolicyUncorrectable Dimm Errors Troubleshooting Dimm Problems Correctable Dimm Errors 1Lines in Ipmi OutputBios Dimm Error Messages Dimm Fault LEDsPage 1DIMMs and LEDs on Motherboard Isolating and Correcting Dimm ECC Errors 2DIMMs and LEDs on Mezzanine BoardReconnect AC power cords to the server Page Event Logs and Post Codes Viewing Event LogsESC Advanced Menu Event Logging Details screen is displayed ESC Power-On Self-Test Post How Bios Post Memory Testing WorksRedirecting Console Output Appendix a Event Logs and Post Codes Select Boot Changing Post OptionsSelect Boot Settings Configuration Boot Settings Configuration screen is displayedPage Post Codes Post Codes Post Code Checkpoints Primary I/O portPost Code Checkpoints Initialize Int-13 and prepare for IPL detection Save system context for Acpi Status Indicator LEDs External Status Indicator LEDsFront Panel LEDs Back Panel LEDsInternal Status Indicator LEDs Hard Drive LEDsFigure B-4DIMMs and LEDs on Motherboard Figure B-5DIMMs and LEDs on Mezzanine Board Page P E N D I X C To start the serial console, type the following commands Making a Serial Connection to the SPViewing Ilom SP Event Logs From the System Monitoring tab, select Event LogsFigure C-1System Event Logs Interpreting Event Log Time Stamps Table C-1Event Log FieldsViewing Replaceable Component Information From the System Information tab, select Components Figure C-2Replaceable Component InformationViewing Sensors Figure C-3Sensor Readings Figure C-4Sensor Details Error Handling Handling of Uncorrectable ErrorsIpmitool sel list Figure D-1DMI Log Screen, Uncorrectable Error Handling of Correctable Errors Appendix D Error Handling Page Handling of Parity Errors Perr NMI Event Handling of System Errors Serr PCI Serr Handling Mismatching Processors Hardware Error Handling Summary Hardware Error Handling SummarySP SEL PCI Serr SP SEL Page Bios IndexPost

X4140, X4440, X4240 specifications

Sun Microsystems was a prominent player in the computing industry, known for its innovative and powerful server systems. Among its notable offerings were the Sun Fire X4240, X4440, and X4140 servers, which made significant inroads in the market for high-performance computing solutions.

The Sun Fire X4240 server was designed to meet the demands of data-intensive applications. It offered impressive scalability, supporting up to 64 GB of DDR2 memory across its eight memory slots. This server utilized AMD Opteron processors, which provided excellent performance thanks to their multi-core architecture. The X4240 also featured a flexible I/O architecture, allowing for various configurations tailored to specific workload requirements.

Next in line was the Sun Fire X4440, which expanded on the capabilities of the X4240. This server was particularly valuable for virtualization and consolidation tasks. It featured up to 128 GB of memory and supported more CPU options, with dual- and quad-core Opteron processors available. The X4440 also included a high-density design that enabled increased storage capacity, accommodating up to 12 SFF drives. This made it ideal for databases and enterprise applications needing fast access to large volumes of data.

Finally, the Sun Fire X4140 brought a balance of performance and efficiency. Like its counterparts, it supported AMD's Opteron processors, delivering robust processing power. The X4140 was designed for environments where space and power efficiency were critical. It was notable for its compact form factor, which allowed organizations to pack more servers into less physical space without sacrificing performance. The server architecture included advanced thermal management technologies, ensuring optimal airflow and cooling, which contributed to reliability in demanding environments.

In terms of connectivity, all three servers featured multiple Gigabit Ethernet ports, offering redundant network connectivity essential for enterprise-level applications. The integrated management interfaces simplified server monitoring and maintenance, ensuring that IT administrators could efficiently manage their resources.

In summary, the Sun Fire X4240, X4440, and X4140 were pivotal servers from Sun Microsystems that provided robust performance, scalability, and efficiency. Their features made them suitable for a variety of workloads, from virtualization to data management, cementing their place in the server market during their era.