METRObility Optical Systems R231-51, R231-61, R231-14, R231-47, R231-59, R231-55 Power, Environmental

Page 21

Singlemode CWDM F/O Interface (R231-47, -49, -51, -53, -55, -57, -59, -61) Connector _____________________________________________________ LC

Wavelength ________________________________________ (see tables below)

Supported Link Length __________________________ up to 60 km full duplex

Cable Type ___________________________________________ 9/125 m F/O

RX Input Sensitivity _______________ -25 dBm (typical); -23 dBm (maximum)

Output Power ___________________________ -3 to +2 dBm; -1 dBm (typical)

Model Number Wavelength

R231-47

1470 nm

 

 

R231-49

1490 nm

 

 

R231-51

1510 nm

 

 

R231-53

1530 nm

Model Number

Wavelength

 

 

R231-55

1550 nm

 

 

R231-57

1570 nm

 

 

R231-59

1590 nm

 

 

R231-61

1610 nm

 

 

Multimode F/O Interface (R231-13, R231-15)

Connector ________________________________________________ ST or SC

Wavelength _______________________________________________ 1310 nm

RX Input Sensitivity ________________________________ -31 dBm minimum

Output Power _______________________ -23.5 dBm to -14 dBm (50/125 m)

_______________________ -20 dBm to -14 dBm (62.5/125 m)

Supported Link Length ___________________________ up to 2 km full duplex

Cable Type ________________________________ 50/125 or 62.5/125 m F/O

Twisted-Pair Interface

Connector __________________________________ Shielded RJ-45, 8-pin jack

Impedance ________________________________________ 100 Ohms nominal

Signal Level Output (differential) __________________________ .95 to 1.05 V

Signal Level Input _________________________________ 350 mV minimum

Supported Link Length ________________________________________ 100 m

Cable Type _________________________________________ Category 5 UTP

(For NEBS Level III and EN55024:1998 compliance, use only Category 5 STP cables.)

Power

Input _______________________________________ 5 V @1.0 A, 5 W average

Environmental

Operating Temperature ____________________________________ 0° to 55° C

Storage Temperature ____________________________________ -30°to 70° C

Operating Humidity _________________________ 5% to 95% non-condensing

Weight _______________________________________________ 5 oz (0.14 kg)

Radiance Access Line Cards

21

Image 21
Contents Installation & User Guide 100Mbps Copper to Fiber Radiance Access Line CardsOverview Overview Radiance Access Line Cards 2Set the Switches MDI-IIto MDI-XSwitch twisted-pair ports only1Unpack the Line Cards Switch Position Function Label DIP SwitchesLink Loss Carry Forward 3Install the Line Card Far End Fault4Connect to the Network Twisted-Pair InterfaceFiber Optic Interface Bwdm Interface Cwdm InterfaceNetwork Connections Factory Settings LED IndicatorsDefault Hardware Switch Settings Label Name Color Status IndicationSoftware Settings Default Software SettingsBandwidth Allocation Maximum Burst SizeLoopback Mode Port Enable/DisableWrite Protect Rmon Statistics Remote Management StatisticsEthernet Statistics Statistic Name DescriptionSinglemode Fiber Optic Power Monitors Input Power LevelOutput Power Level Link Loss Carry Forward Llcf Link Loss Return LLR Topology Solutions Technical Specifications Data RateNetwork Connections Environmental PowerCSA Product Safety, EMC and Compliance StatementsThree-Year Warranty for the Radiance Access Line Card Warranty and ServicingProduct Manuals