3. General Functions

Cable Length Meter

3. General Functions

3.1 PWR Key and Auto Power Off

Press the PWR key to turn the unit on and off. If no keys have been pressed, the Cable Length Meter powers off automatically after 10 minutes. The timer resets every time you press a key. In Tone mode, the unit will automatically power off after 1 hour.

3.2 Mode Key

The Cable Length Meter operates in eight modes. Press the “Mode” key to cycle through the various modes:

AWG/mm/mm2 mode: measures cable length in AWG/mm/mm2, feet/meters, copper/aluminum

Coax mode: measures cable length, distance to opens, or distance to short

Telco mode: measures cable length, distance to opens or distance to short

Network: measures cable length, distance to opens, or distance to short

Ohm: measures resistance from 0 to 635 ohms

Tone: generates four different tones

3.3 AL/CU Units Key

The AL/CU key functions in two ways.

Function #1: Press the AL/CU/Units key to select wire alloy type: copper (CU) or aluminum (AL). When selected, the “AL” or “CU” icon will light in the lower right corner of the display.

Function #2: Hold the AL/CU/Units key down for approximately 1.5 seconds. The unit will toggle between “Feet” or “Meters”. When selected, the “FT” or“M” icon will light in the center right hand side of the screen.