Paradyne BSX8000-5, Broadband Services Switch CLI Commands 2 Description, Clearnvram

Page 12

Table 1. CLI Commands (2 of 2)

Command

Description

 

 

CLEAR_NVRAM

If no interface modules are present in the chassis, clears

 

Non-Volatile Random Access Memory, restoring the

 

DSLAM to factory defaults.

 

 

DISABLE_TELNET

Disables access to the DSLAM using Telnet.

 

 

DISABLE_TFTP

Disables access to the DSLAM using Trivial File Transfer

 

Protocol.

 

 

DISABLE_WEB_SERVER]

Disables access to the DSLAM using the web server.

 

 

ENABLE_TELNET

Enables access to the DSLAM using Telnet.

 

 

ENABLE_TFTP

Enables access to the DSLAM using Trivial File Transfer

 

Protocol.

 

 

ENABLE_WEB_SERVER

Enables access to the DSLAM using the web server.

 

 

HELP

Lists available commands and their syntax.

 

 

LOGOUT

Ends the CLI session.

 

 

SET

Sets a configuration option. Most SET commands require

 

that slot be specified, and allow port optionally to be

 

specified. Exceptions are the two system SET commands

 

for session timeout and system name.

 

Syntax:

 

set cli_session_timeout seconds

 

set system_name name

 

set slot 1 [[port] [all, port_number]] [item] [value]

 

Items and values for SET commands are shown in the CLI

 

help.

 

 

SHOW

Shows a configuration option. SHOW commands require

 

that slot be specified, and allow port optionally to be

 

specified.

 

Syntax:

 

show slot 1 [[port] [all, port_number]] [item] [value]

 

Items and values for SHOW commands are shown in the

 

CLI help.

 

 

WHO

Shows who is logged in the system.

 

 

12

March 2005

BSX8-A2-GZ40-10

Image 12
Contents Contents Software and Firmware License AgreementPage BSX8000-5 Overview Product Documentation OnlineRelease Notes Installing a Micro Interface Module MIM in the BSX8000-5 Unpacking and Inspecting the EquipmentInstalling the BSX8000-5 in a BLC Connect the MIM to the NetworkMIM-10/100 MIM-2000FBLC Management Web Interface NMSMIM-4000F Configuring Your Windows PC to Communicate with NMS NMS home page appears NMS Management Configuration Parameter DescriptionCommand Line Interface CLI CLI System RequirementsConnecting a PC Directly CLI CommandsCLI Commands 1 Description Launching the Terminal Emulation ProgramCLI Commands 2 Description ClearnvramLED Indicators LED States and MeaningsState Indication Additional Information 10/100/1000BaseT Connectors 100/1000 Pinouts SignalDB9 to RJ45 Adapter Pinouts Warranty, Sales, Service, and Training Information Regulatory Compliance for Class a EquipmentUS Federal Communications Commission FCC Industry Canada EuropeBSX8-A2-GZ40-10