Paradyne 9109 OCU-DP technical manual Installing the APM

Page 6

Installing the APM

The APM can be installed in any slot except Slot 01.

CAUTION:

You must insert the OCU-DP APM in the correct slot so that it mates with its matching I/O card. APMs are keyed so that they mate only with their matching I/O cards.

1.Remove the filler panel, if applicable. See the installation instructions that came with your housing for information.

2.Remove the APM from the shipping box. Handle only by the top and bottom edges to avoid damaging the card.

3.At the front of the housing, align the APM with the upper and lower tracks of the selected slot.

5-Slot

2-Slot

Ejector

Latches

Front View

Ejector

Latches

98-15152-02

4.Slide the APM into the tracks until it seats with the midplane connectors. Be careful not to force the card or bend any pins.

5.Close both the upper and lower ejector latches on the housing to lock in place, then tighten the captive screws on the ejector latches.

6

Image 6
Contents Product Documentation on the World Wide Web Before You BeginPackage Checklist Equipment You May Need to OrderOCU-DP APM Installing the I/O Card Rear ViewOCU Connecting to the DDS InterfaceRJ48S DDS DSURemoving the Housings Bezel Installing the APM Removing/Replacing a Card APMDocument Feedback Power-OnWarranty, Sales, Service, and Training Information Trademarks