Paradyne SAM2000G-12 manual SAM2000G Management, SAM2000G Port Parameters

Page 4

PARAMETER

DEFAULT CONFIGURATION

Gateway

0.0.0.0

Inband Management

off

Inband Management VLAN ID

0 (off)

IP Address: IPD12000 Slot 13

192.168.254.252

IP Address: IPD12000 Slot 14

192.168.254.253

IP Address: IPD4000 Slot 5

192.168.254.252

Management IP Address Filter Range

0.0.0.0 - 255.255.255.255 (all)

Subnet Mask

255.255.255.0

3.2SAM2000G Port Parameters

PARAMETER

DEFAULT CONFIGURATION

Circuit Identification

n/a (no default)

Back-bone VLAN

0 (off)

Flood

uplink

IP Range 1

0.0.0.0 - 255.255.255.255 (all)

IP Range 2

0.0.0.0 - 0.0.0.0

Priority (VLAN)

0 (none)

Protocol

all

Speed

272 kbps

VLAN Range

0 - 0 (off)

4.0SAM2000G MANAGEMENT

Once your SAM2000G has been installed, bandwidth and other configurations are software selectable via your IP DSLAM's MUM. Dependent upon the MUM model installed, the SAM2000G may be configured via Command Line Interface (CLI), Simple Network Management Protocol (SNMP) and/or Net to Net Technologies' web-based Network Management System (NMS).

If your IP DSLAM is newly installed, configuration of the DSLAM's IP Address, Subnet Mask and Gateway must be completed, via CLI or NMS, before you will be able to access management data or configure any other parameters. Refer to the CLI Management User Guide (http://www.nettonet.com/support/docs/210- 0000052) or to the NMS Management User Guide (http://www.nettonet.com/support/docs/210-

0000048) for initial configuration instructions.

210-0000026 rev07

Image 4
Contents Sdsl Access Module Models SAM2000G-12SAM2000Q-12 SAM2000-12Installation Install the SAM2000G in an IP Dslam ChassisUnpack and Inspect the SAM2000G Connect the Shdsl LinesSAM2000G Default Configurations IP Dslam ManagementSAM2000G Management SAM2000G Port ParametersVia Command Line Interface CLI Via Net to Nets Network Management System NMSBandwidth and Distance Via Simple Network Management Protocol SnmpAdditional Information Data StorageData Needed for Backup Example LED IndicationsRegulatory Compliance for Class a Equipment Reception RxWorldwide Headquarters Emea Headquarters