Table 2. Port Configuration Options (3 of 3)
Option | Factory 1 | Factory 2 | Comments/Description | |
|
|
|
| |
| Disab | Disab | Specifies whether the device will | |
|
| maintain | ||
Maint | Maint | |||
| statistics. | |||
|
|
|
| |
| Enab | Enab | Specifies whether the EDL | |
Mgmt Link: |
|
| ||
Disab | Disab | Management Link is enabled. | ||
| ||||
|
| |||
|
|
|
|
Table 3. Network Interface Configuration Options
Option | Factory 1 | Factory 2 | Comments/Description | ||
|
|
|
|
| |
NET Framing: | D4 | D4 | Selects D4 or ESF framing format. |
| |
|
|
| |||
ESF | ESF |
| |||
|
|
| |||
|
|
|
|
| |
NET Coding: | AMI | AMI | Selects AMI or B8ZS line coding |
| |
|
|
| |||
B8ZS | B8ZS | format. | |||
| |||||
|
|
|
|
| |
| 0.0 | 0.0 |
|
| |
|
|
|
|
| |
LBO: | ±7.5 | ±7.5 | Provides Line Build Out in dB. | ||
|
| ||||
±15 | ±15 | ||||
|
|
| |||
|
|
|
|
| |
| ±22.5 | ±22.5 |
|
| |
|
|
|
|
| |
ANSI PRM: | Enab | Enab | Sends ANSI Performance Report | ||
|
| ||||
Disab | Disab | Messages. | |||
| |||||
|
|
|
|
| |
Mgmt Link: | Enab | Enab | Specifies whether the FDL's | ||
|
| ||||
Disab | Disab | Management Link is enabled. | |||
| |||||
|
|
|
|
| |
NET LLB: | Enab | Enab | |||
|
| ||||
Disab | Disab | be controlled by inband LLB codes. | |||
| |||||
|
|
|
| ||
| Enab | Enab | |||
NET PLB: |
|
| to be controlled by FDL PLB | ||
Disab | Disab | ||||
| messages. | ||||
|
|
| |||
|
|
|
| ||
| 62411 | 62411 | Provides enforcement of ones | ||
|
|
| density protection per AT&T TR | ||
BitStuff: | Part68 | Part68 | |||
62411, ANSI | |||||
|
|
| |||
| Disab | Disab | Part 68 Technical Publication. | ||
|
|
|
|
| |
Circuit Ident: | Edit | Edit | Specifies the transmission vendor's | ||
|
| ||||
| Clear | Clear | circuit identifier. | ||
|
|
|
|
|
7