Paradyne 4300 Inspecting Shipment, Warranty, Sales, Service, and Training Information, Trademarks

Page 3
Inspecting Shipment

4300 Remote Broadband Access Concentrator Installation Instructions

Inspecting Shipment

On receipt of the equipment, inspect the shipping container(s) and note any signs of damage. Then unpack the container(s) and carefully inspect for damage to the contents. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and your sales representative.

Warranty, Sales, Service, and Training Information

Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:

Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.)

Telephone: Call our automated system to receive current information by fax or to speak with a company representative.

Within the U.S.A., call 1-800-870-2221

Outside the U.S.A., call 1-727-530-2340

Trademarks

GranDSLAM is a registered trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.

Product Overview

The 4300 Remote BAC is a pole-mounted or wall-mounted outdoor telecommunications equipment cabinet. The cabinet has overall dimensions of 26 inches high x 19 inches deep x 22 inches wide. See the figures on the following pages for details.

The cabinet is constructed of aluminum with a powder coat painted finish for reduced weight and superior corrosion resistance. The front door is equipped with a quarter turn padlockable door latch. The top of the cabinet has a double wall construction to reduce the effects of solar radiation and for structural integrity.

Cooling is provided by a –48 VDC fan ventilation system. The fan is mounted to the roof of the cabinet behind the equipment. The fan pulls air through the front door of the cabinet and exhausts the air through the roof overhang and the louvers in the sides of the roof.

The left front of the equipment-mounting bay has 6U (10.5 inches) of 19" rack space provided for mounting up to three GranDSLAM 4200 assemblies (1U each) and a rectifier or a DC-DC converter (2U each). An additional 1U is provided for future expansion. Two swing-out 19” racks are provided on the right side of the equipment bay for mounting up to four 50 pair protection/cross connect assemblies (200 pair capacity). Each protection/cross connect swing-out rack has 4U of 19” rack space (8U total).

Cable entry and exit from the cabinet passes through two sealing boots located in the bottom rear of the equipment bay. The master grounding bus bar is located on the rear wall of the equipment bay on the left side. AC and DC power centers are mounted to the rear wall on the right side.

4300-A2-GZ40-00

July 2004

3

Image 3
Contents Document Number 4300-A2-GZ40-00 ContentsInstallation Instructions 4300 Remote Broadband Access ConcentratorProduct Documentation Online Using This Installation GuideTrademarks Warranty, Sales, Service, and Training InformationInspecting Shipment Product OverviewConnect Panels Swing out racks for Protection/Cross Connect Panels Figure A - Front view of cabinet with door openRectifier or DC-DC Converter Cabinet lifting eyelets GranDSLAM DSLAMs Protection/CrossFigure B - Front view of cabinet without equipment CABINET CONFIGURATIONSTable 1 - Expansion, Mounting and Maintenance Kits EXPANSION, MOUNTING AND MAINTENANCE KITSFigure C - Cabinet overall dimensions PRODUCT SPECIFICATIONSFigure D - Quarter turn locking door latches QUARTER-TURN LOCKING DOOR LATCHESLifting eyelets are provided to facilitate hoisting if desired Installation ProcedureCLEARANCE REQUIREMENTS Figure E - Cabinet FootprintFigure F - Pole Mounting Diagram INSTALLATION PROCEDURE FOR POLE MOUNTINGHave the following equipment ready before beginning this procedure Figure G - Wall Mounting Diagram INSTALLATION PROCEDURE FOR WALL MOUNTINGLifting eyelets are provided to facilitate hoisting if desired Cabinet Grounding Information GROUND WIREFigure H - Grounding Diagram GROUNDING DIAGRAM AND PROCEDUREunterminated Protection/Cross ConnectsFigure I - Protection/Cross Connect Panel, top view 50 pair Figure J -Cross Connect Panel, front viewConnector POTS Protection/Cross Connect Wiring TablesTable 2 - Protection Cross Connect Cable Wiring Connector DSLWHITE / BROWN Table 3 - Cross Connect Panel WiringWHITE / ORANGE WHITE / BLUEFan/Filter Replacement Figure K - Fan/Filter Replacement DiagramFilter Maintenance Figure L - Model 1 Schematic Wiring Diagram EXTERNAL WIRINGLINE POWER SCHEMATIC WIRING DIAGRAMSFigure M - Model 2 Schematic Wiring Diagram 4300-A2-GZ40-00 Figure N - Model 3 Schematic Wiring Diagram