Paradyne 4300 Figure B - Front view of cabinet without equipment, Cabinet Configurations

Page 5
Figure B - Front view of cabinet without equipment

4300 Remote Broadband Access Concentrator Installation Instructions

Ground Bus Bar

AC Input Panel for Model 2

DC Input Panel for Model 3

Air Filters

Cable Management

Brackets

Cable Entry Ports

DC Distribution Box

 

Figure B - Front view of cabinet without equipment

CABINET CONFIGURATIONS

Three basic cabinet configurations are offered as explained below. Expansion kits are provided to increase the capacity of each configuration to up to three GranDSLAM 4200 DSLAMs. Kits are also provided for fan and filter replacement and for pole or wall mounting brackets.

Model numbers are of the form 43WX-P1-Y0Z, where:

W is the DSL type (1 for ReachDSL, 2 for ADSL, 3 for ADSL Annex B, 7 for SHDSL)

X is the uplink type (1 for T1 ATM, 2 for E1 ATM, 3 for 8-port T1/E1 IMA, 9 for 10/100/1000BaseT/GigE fiber)

Y is the power type (1 for externally-fed –48/–60 VDC, 2 for AC, 3 for line power)

Z is the splitter option (0 for 900 ohm, 1 for 600 ohm)

The three basic cabinet configurations are:

Model 1 (Feature Number 43xx-P1-10x) - Cabinet to be used at existing remote terminal sites, where the RT can supply –48 VDC power. This model will be wired for one GranDSLAM assembly.

Model 2 (Feature Number 43xx-P1-20x)Cabinet to be used where AC power is available. This model will be wired for one GranDSLAM assembly and will include an AC load center and a –48 VDC rectifier.

Model 3 (Feature Number 43xx-P1-30x)Cabinet to be used where AC power is not available. Power to the cabinet will be provided by up to 25 common pairs. The tips and rings of the pairs are bussed together and fed to a DC-DC converter, which provides the –48 VDC power to the GranDSLAM assemblies. The input voltage to the DC-DC converter is 90 to 400 VDC. This model will be wired for one GranDSLAM assembly.

4300-A2-GZ40-00

July 2004

5

Image 5
Contents Installation Instructions Contents4300 Remote Broadband Access Concentrator Document Number 4300-A2-GZ40-00Product Documentation Online Using This Installation GuideInspecting Shipment Warranty, Sales, Service, and Training InformationProduct Overview TrademarksRectifier or DC-DC Converter Figure A - Front view of cabinet with door openCabinet lifting eyelets GranDSLAM DSLAMs Protection/Cross Connect Panels Swing out racks for Protection/Cross Connect PanelsFigure B - Front view of cabinet without equipment CABINET CONFIGURATIONSTable 1 - Expansion, Mounting and Maintenance Kits EXPANSION, MOUNTING AND MAINTENANCE KITSFigure C - Cabinet overall dimensions PRODUCT SPECIFICATIONSFigure D - Quarter turn locking door latches QUARTER-TURN LOCKING DOOR LATCHESCLEARANCE REQUIREMENTS Installation ProcedureFigure E - Cabinet Footprint Lifting eyelets are provided to facilitate hoisting if desiredFigure F - Pole Mounting Diagram INSTALLATION PROCEDURE FOR POLE MOUNTINGHave the following equipment ready before beginning this procedure Figure G - Wall Mounting Diagram INSTALLATION PROCEDURE FOR WALL MOUNTINGLifting eyelets are provided to facilitate hoisting if desired Cabinet Grounding Information GROUND WIREFigure H - Grounding Diagram GROUNDING DIAGRAM AND PROCEDUREFigure I - Protection/Cross Connect Panel, top view 50 pair Protection/Cross ConnectsFigure J -Cross Connect Panel, front view unterminatedTable 2 - Protection Cross Connect Cable Wiring Protection/Cross Connect Wiring TablesConnector DSL Connector POTSWHITE / ORANGE Table 3 - Cross Connect Panel WiringWHITE / BLUE WHITE / BROWNFilter Maintenance Fan/Filter ReplacementFigure K - Fan/Filter Replacement Diagram LINE POWER EXTERNAL WIRINGSCHEMATIC WIRING DIAGRAMS Figure L - Model 1 Schematic Wiring DiagramFigure M - Model 2 Schematic Wiring Diagram 4300-A2-GZ40-00 Figure N - Model 3 Schematic Wiring Diagram