XS712T Smart Switch
2.Next to the Summer Time field, select one of the following options:
•Recurring. Summer time occurs at the same time every year. The start and end times and dates for the time shift must be manually configured.
•Recurring EU. The system clock uses the standard recurring summer time settings used in countries in the European Union. When this field is selected, the rest of the applicable fields on the screen are automatically populated and cannot be edited.
•Recurring USA. The system clock uses the standard recurring daylight saving time settings used in the United States. When this field is selected, the rest of the applicable fields on the screen are automatically populated and cannot be edited.
•
3.If the selected summer time mode is Recurring or Non Recurring, set the start and end times for the time shift:
•Begins At: From the appropriate lists, select the date and time on which summer time begins.
•Ends At: From the appropriate lists, select the date and time on which summer time ends.
4.Next to the Offset field, specify the number of minutes to shift the summer time from the standard time.
5.Next to the Zone field, specify the acronym associated with the time zone when summer time is in effect.
This field is not validated against an official list of time zone acronyms.
6.Click Apply.
The Summer Time Status table shows information about the summer time settings and whether the time shift for summer time is currently in effect.
Denial of Service
Use the Denial of Service (DoS) feature to configure DoS control. The switch software provides support for classifying and blocking specific types of DoS attacks.
Configure Auto-DoS
The
To enable the Auto-DoS feature:
1.Select System > Management > Denial of Service >
40