3.From the Severity Filter field, specify the type of log messages to record.

A log records messages equal to or above a configured severity threshold. For example, if you select Error, the logged messages include Error, Critical, Alert, and Emergency. The default severity level is Alert (1). The severity can be one of the following levels:

Emergency (0). The highest warning level. If the device is down or not functioning properly, an emergency log is saved to the device.

Alert (1). The second highest warning level. An alert log is saved if there is a serious device malfunction, such as all device features being down. Action must be taken immediately.

Critical (2). The third highest warning level. A critical log is saved if a critical device malfunction occurs, for example, two device ports are not functioning, while the rest of the device ports remain functional.

Error (3). A device error has occurred, such as if a port is offline.

Warning (4). The lowest level of a device warning.

Notice (5). Normal but significant conditions. Provides the network administrators with device information.

Informational (6). Provides device information.

Debug (7). Provides detailed information about the log. Debugging should only be entered by qualified support personnel.

4.Click Apply.

The rest of the screen displays the number of persistent messages the system has logged and the persistent log messages.

Use the buttons at the bottom of the screen to perform the following actions:

Click Clear to clear the messages out of the buffered log.

Click Refresh to refresh the screen with the most current data from the switch.