XS712T Smart Switch

Table 6. Time Configuration status fields (Continued)

Field

Description

Address Type

Specifies the address type of the SNTP Server address for the last

 

received valid packet.

Server Stratum

Specifies the claimed stratum of the server for the last received valid

 

packet.

 

 

Reference Clock Id

Specifies the reference clock identifier of the server for the last received

 

valid packet.

 

 

Server Mode

Specifies the mode of the server for the last received valid packet.

 

 

Unicast Sever Max Entries

Specifies the maximum number of unicast server entries that can be

 

configured on this client.

 

 

Unicast Server Current

Specifies the number of current valid unicast server entries configured

Entries

for this client.

Click Refresh to refresh the screen with the most current data from the switch.

SNTP Server Configuration

Use the SNTP Server Configuration screen to view and modify information for adding and modifying Simple Network Time Protocol SNTP servers.

To configure a new SNTP server:

1.Select System > Management > Time > SNTP Server Configuration. The SNTP Server Configuration screen displays.

2.From the Server Type list, select the type of SNTP address to enter in the Address field, which is either an IP address (IPv4) or hostname (DNS).

3.Under the Address field, specify the IP address or the hostname of the SNTP server.

4.If the UDP port on the SNTP server to which SNTP requests are sent is not the standard port (123), specify the port number.

37

Page 37
Image 37
NETGEAR XS712T-100NES manual Sntp Server Configuration,  To configure a new Sntp server