Quatech DSC-200/300 Clock Rate and Optional Registers, Enable Scratchpad Register SPAD, J13

Page 11

2.4 Clock Rate and Optional Registers

Figure 3 shows the jumper configuration as shipped from the factory, with two spare jumpers applied in neutral positions. Remove one or both and apply as shown in following subsections to set optional features.

J10

J11

J12

J13

X2

X4

X8

SPAD

Figure 3 --- Factory default clock rate and options settings

2.4.1 Enable Scratchpad Register (SPAD, J13)

In the default configuration, an Interrupt Status Register and an Options Register (see page 10) replace the scratchpad (base address + 7) of each UART. If the SPAD jumper is applied as in Figure 4, the UART scratchpad registers are enabled, and the Interrupt Status Register and the Options Register are not available.

J10

J11

J12

J13

X2

X4

X8

SPAD

Figure 4 --- Enable scratchpad registers

Quatech DSC-200/300 User's Manual

11

Image 11
Contents DSC-200/300 Warranty Information Page Declaration of Conformity Manufacturers Name Base Address and Interrupt Level IRQ RS-422 or RS-485 Signal Line TerminationUsing the New Hardware Found Wizard Address Map and Special RegistersPage General Information IND Option --- Surge Suppression Upgrade FeaturesFactory default signal termination settings Hardware ConfigurationFull-duplex/Half-duplex Operation Signal ConnectionsClock Rate and Optional Registers Enable Scratchpad Register SPAD, J13Clock multiplier jumper options Force High-Speed Uart Clock X2, X4, or X8, J10-J12Jumper/connector locations Hardware InstallationChannel Address Range Interrupt Status Register Enabling the Special RegistersBit Name Description Options RegisterRR1 RR0 Clock Rate MultiplierWindows Millennium Windows ConfigurationWindows Windows Windows Page Using the New Hardware Found Wizard Windows NT QTPCI.EXE DOS and Other Operating SystemsQTPCI.EXE Basic Mode display QTPCI.EXE Expert Mode display OS/2 Jumper/Channel correspondence External ConnectionsRclk RTS/CTS HandshakeAUXIN/AUXOUT Loopback XclkHalf-Duplex/Full-Duplex Selection Half- or full-duplex selection RS-422/485 Line termination resistance values Termination ResistorsRS-422/485 Peripheral Connection DSC-200/300 connector definitionsINTA# PCI Resource Map10Specifications Computer will not boot up TroubleshootingDSC-200/300 Revision March