JB6 & JB7: DTE as DSR or RI
Because this rear card is designed to function with a variety of rack cards, it comes equipped with two strap positions. However, when used with the Model 1012ARC, this strap must be installed only in one position. Place the jumper across pins 1&2 so that the terminal (DTE) sees DSR as high when the DTE raises DTR. The other positions— across pins 2&3, are for Ring Indicate as defined by
JB6 & JB7 | Setting |
Position 1&2 | DSR (default) |
Position 2&3 | N/A |
7
4.0 INSTALLATION
This section describes the functions of the Model 1000R16 rack chassis, tells how to install front and rear Model 1012ARC cards and provides diagrams for correctly wiring the interface connections.
4.1 THE MODEL 1000R16 RACK CHASSIS
The Model 1000R16 Rack Chassis (Figure 5) has sixteen short range modem card slots, plus its own power supply. Measuring only 3.5” high, the Model 1000R16 occupies only 2U in a 19” rack. Sturdy front handles allow the Model 1000R16 to be transported conveniently.
Figure 5. Model 1000R16 Rack Chassis with power supply
4.1.1 The Rack Power Supply
The power supply included in the Model 1000R16 rack uses the same
The front card is then secured by thumb screws and the rear card by conventional metal screws.
WARNING! There are no
(continued)
8