Patton electronic Asynchronous, 1012ARC Cable Recommendations, Wire Gauge Capacitance Resistance

Page 9

APPENDIX B

CABLE RECOMMENDATIONS

The Patton Model 1012ARC operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted-pair cable with the following characteristics:

Wire Gauge

Capacitance

Resistance

19 AWG

83nf/mi or 15.72 pf/ft.

.0163 Ohms/ft.

22 AWG

83nf/mi or 15.72 pf/ft.

.0326 Ohms/ft.

24 AWG

83nf/mi or 15.72 pf/ft.

.05165 Ohms/ft.

Using or simulating cable with the above characteristics, the following data rate/distance results were obtained by Patton during bench tests:

Data Rate (Bps)

Gauge (AWG) / Distance (Mi)

 

19

24

26

Up to 38,400

6.0

3.5

2.0

To gain optimum performance from the Model 1012ARC, please keep the following guidelines in mind:

Always use twisted pair wire—this is not an option.

Use twisted pair wire with a capacitance of 20pf/ft or less.

Avoid twisted pair wire thinner than 26 AWG (i.e. avoid AWG numbers higher AWG numbers than 26)

Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainable. Functionality should not be affected.

Many environmental factors can affect the maximum distances obtainable at a particular site. Use the above data rate/distance table as a general guideline only.

APPENDIX C

FACTORY REPLACEMENT PARTS

The Patton Model 1012ARC rack system features interchangeable rear cards, power cords/fuses for international various operating environments and other user-replaceable parts. Model numbers and descriptions for these parts are listed below:

Patton Model #

Description

1000RPEM

120/240V Rear Power Entry Module

1000RPSM-2

120/240V Front Power Supply Module

1000RPEM-DC

DC Rear Power Entry Module

1000RPSM-48A

48V Front Power Supply Module

1000RPEM-V

120/240V CE Compliant Rear Power

 

Entry Module

1000RPSM-V

120/240V CE Compliant Front Power

 

Supply Module

0805US

American Power Cord

0805EUR

European Power Cord CEE 7

0805UK

United Kingdom Power Cord

0805AUS

Australia/New Zealand Power Cord

0805DEN

Denmark Power Cord

0805FR

France/Belgium Power Cord

0805IN

India Power Cord

0805IS

Israel Power Cord

0805JAP

Japan Power Cord

0805SW

Switzerland Power Cord

0516FPB1

Single Width Blank Front Panel

0516FPB4

4-Wide Blank Front Panel

0516RPB1

Single Width Blank Rear Panel

0516RPB4

4-Wide Blank Rear Panel

0821R4

400 mA Fuse (5x20mm)

 

Littlefuse 239.400 or equivalent

0821R2

200 mA Fuse (5x20mm)

 

Littlefuse 239.200 or equivalent

056S1

Set of 16 #4 pan head screws/washers

15

16

Image 9
Contents User Manual Radio and TV Interference ServiceCE Notice Monday through FridayMoving the Configuration Straps FeaturesSetting the RTS/DCD Straps DescriptionRear Card Strap Settings Rear Card ConfigurationInterface Card Strap Summary Table #1 JB5 Sgnd & FrgndRack Power Supply JB6 & JB7 DTE as DSR or RIModel 1000R16 Rack Chassis Signal PIN# Color ‡ Installing the Model 1012ARC Into the ChassisTerminal Interface Connection Twisted Pair ConnectionMultipoint Twisted Pair Connection Host First Slave Second SlaveLED Status Monitors Specifications POWER-UPRTS/CTS Delay 40mS Temperature Range 0-50C32-122FFactory Replacement Parts Wire Gauge Capacitance ResistanceCable Recommendations Data Rate Bps Gauge AWG / Distance Mi Up to 38,400Interface Settings Patton Modular Interface 8/10 Wire RJ-45Block Diagram