5.2 POWER-UP
There is no power switch on the Model 1012ARC: Power is automatically applied to the Model 1012ARC when its
it while the rack’s power supply is switched on.
When the local and remote Model 1012ARCs are both powered up and are passing data normally, the following LED conditions will exist:
•PWR = solid green
•TD & RD = flashing
•CD = solid green
APPENDIX A
SPECIFICATIONS
Transmission Format: Asynchronous, half or full duplex
Transmission Line: Two unconditioned twisted pair 19 - 26 AWG
Transmit Level: -6 dBm
Operation:
Interfaces: EIA
Data Rates: To 38.4 Kbps
Isolation: Minimum 1500 V RMS transformer coupled
Surge Protection: Silicon Avalanche Diodes
RTS/CTS Delay: 40mS
Connectors:
Power Supply:
Internal Interface: Connection to the Model 1000R16 rack chassis via 50 pin male card edge
Fuse: 400mA for 120V applications; 200mA for 240V applications
Temperature Range: 0-50°C (32-122°F)
Altitude:
Humidity: Up to 95%
Dimensions: 0.95”w x 3.1”h x 5.4”l
13 | 14 |