MAIN MENU Option 7: Test Modes

Select Option 7 from the MAIN MENU to select the test mode status of the Model 1092. (below). The Model 1092 Test Mode settings help to verify the integrity of the data link and isolate communication difficulties.

NOTE: An error counter is displayed when the unit is in one of the above test modes except LLB and RDL.

To run or terminate a particular test, key in the option to get to that screen menu. If a particular test cannot be invoked, the unit displays the message:

“Attempt unsuccessful!”.

Test Mode options 2,3,7,8 and 9 require the 1092 to be in Data Mode with the remote 1092. The Model 1092 Test Modes are described below:

OFF

Terminates all tests

511

Initiates the built-in test pattern generator

 

and detector.

511 with Errors

Initiates the built-in test pattern generator

 

and detector. The test pattern generator

 

also injects intentional errors approximately

 

once per second.

Local Line Loop

Initiates the Local Line Loop test and starts

and 511

the internal 511 generator and detector.

Local Line Loop Initiates the Local Line Loop test and starts

and 511 w/errors the internal 511 generator and detector. In this test, the 511 pattern generator injects intentional errors into the data stream.

Remote Digital Initiates the Remote Digital Loopback test.

LoopAny data sent to the remote 1092 is returned to the originating device.

Remote Digital Initiates the Remote Digital Loopback test

Loop and 511 and starts the internal 511 generator and detectors.

Remote Digital Initiates the Remote Digital Loopback test

Loop andand starts the 511test patterns. In this test

511 with errors the 511 pattern generator will inject initial errors into the data stream.

The Modem Status Screen is displayed upon initiating a test. A 511 error counter is displayed to indicate errors. Press the ‘C’ key to clear the counter and redisplay the Modem Status Screen. Pressing ‘ESC’ returns you to the Test Mode Menu.

Pressing “C” will clear the error count and redisplay the modem status screen. Pressing Return will update and redisplay the status.

17

18

Image 10
Contents Model Radio and TV Interference CE NoticeTel 301 Email support@patton.com ServiceFeatures DescriptionSwitches S1-1 and S1-2 Data Rate Configuring the Hardware DIP SwitchesConfiguration DIP Switch Set S1 Switch S1-3 Data Set Ready During Line Loopback TestS2 Summary Table Switches S2-7 and S2-8 Control Port Data Rate Switch S2-3 Response to Local Line Loop Requests from DTEConfiguring the Software Switches Main Menu Option 2 Display Hardware Configuration Configuring the LocalMain Menu Option 1 Display Active Configuration Main Menu Option 3 Display Software ConfigurationData Format Clock ModeDTE Rate DSR During Local Line LoopDTE Controlled Remote Digital Loop Response to Remote Digital LoopDTE Controlled Local Line Loop Main Menu Option 5 Select Hardware/Software ControlOFF With ErrorsMain Menu Option 7 Test Modes 511Remote Main Menu Option 2 Remote Unit Configuration Configuring the RemoteRemote Main Menu Option 1 Display Remote Unit Configuration Remote Main Menu Option 3 Display Remote Modem StatusConnection to the Serial Port Signal PIN#Connection to the Twisted Pair Interface Changing QuikConnect ModulesPower Connection Installing the New QuikConnect ModuleConfiguring the X.21 QuikConnect Module Connection to a DTE DeviceTD & RD POWER-UPLED Status Monitors CTSUsing the V.52 BER Test Pattern Generator Using Local Line Loopback LLBUsing Remote Digital Loopback RDL Test ModesPatton Model 1092 Specifications Temperature Range 32-122F 0 -50CPatton Model # Description Patton Model 1092 Interface PIN AssignmentPin # Signal Frame Ground Appendix D Patton Model 1092 Pin Out Control Port