Patton electronic 1092 user manual Response to Remote Digital Loop, DTE Controlled Local Line Loop

Page 9

5. Response to Remote Digital Loop

Select Option 5 in the SOFTWARE CONFIGURATION Menu to instruct the Model 1092 to either respond or ignore the Remote Digital Loop request from the remote 1092.

6. DTE Controlled Local Line Loop

Select Option 6 in the SOFTWARE CONFIGURATION Menu to instruct the Model 1092 to either respond or ignore Local Line Loop requests from the DTE. To instruct the Model 1092 to respond to Local Line Loop requests from the DTE, select Enable (Option 1). To instruct the 1092 to ignore Local Line Loop requests from the DTE interface, select Disable (Option 2).

7. DTE Controlled Remote Digital Loop

Select Option 7 in the SOFTWARE CONFIGURATION Menu to enable DTE control of the Remote Digital Loop Menu (See below). The Remote Digital Loop on the 1092 can be controlled from the DTE interface by selecting Enable (Option 1). To instruct the 1092 to ignore this request from the DTE interface, select Disable (Option 2).

MAIN MENU Option 5: Select Hardware/Software Control

Select Option 5 from the MAIN MENU selects whether the Model 1092 will use the hardware switch settings or the software switch settings for its active configuration. If Options 1 or 2 are selected, the 1092RC will use the current hardware or software switch settings as the active configuration. After changing this setting select MAIN MENU Option 8 to implement the changes.

MAIN MENU Option 6: Display Modem Status

Select Option 6 from MAIN MENU to display the Modem Status (below). Press RETURN on the keyboard to update and redisplay the screen.

NOTE: Valid Model 1092 Handshake Statuses are listed below:

1)Handshaking - This status occurs when the 1092 is in the process of establishing a link with another 1092.

2)Data Mode - This status occurs when the 1092 successfully establishes a link with another 1092 allowing the data to flow.

15

16

Image 9
Contents Model CE Notice Radio and TV InterferenceFeatures ServiceTel 301 Email support@patton.com DescriptionConfiguration DIP Switch Set S1 Configuring the Hardware DIP SwitchesSwitches S1-1 and S1-2 Data Rate Switch S1-3 Data Set Ready During Line Loopback TestS2 Summary Table Switch S2-3 Response to Local Line Loop Requests from DTE Switches S2-7 and S2-8 Control Port Data RateConfiguring the Software Switches Main Menu Option 1 Display Active Configuration Configuring the LocalMain Menu Option 2 Display Hardware Configuration Main Menu Option 3 Display Software ConfigurationDTE Rate Clock ModeData Format DSR During Local Line LoopDTE Controlled Local Line Loop Response to Remote Digital LoopDTE Controlled Remote Digital Loop Main Menu Option 5 Select Hardware/Software ControlMain Menu Option 7 Test Modes With ErrorsOFF 511Remote Main Menu Option 1 Display Remote Unit Configuration Configuring the RemoteRemote Main Menu Option 2 Remote Unit Configuration Remote Main Menu Option 3 Display Remote Modem StatusConnection to the Twisted Pair Interface Signal PIN#Connection to the Serial Port Changing QuikConnect ModulesConfiguring the X.21 QuikConnect Module Installing the New QuikConnect ModulePower Connection Connection to a DTE DeviceLED Status Monitors POWER-UPTD & RD CTSUsing Remote Digital Loopback RDL Using Local Line Loopback LLBUsing the V.52 BER Test Pattern Generator Test ModesTemperature Range 32-122F 0 -50C Patton Model 1092 SpecificationsPatton Model 1092 Interface PIN Assignment Patton Model # DescriptionPin # Signal Frame Ground Patton Model 1092 Pin Out Control Port Appendix D