3.4 CONFIGURATION SWITCH SET “S3”
The DIP switches on S3 set the
S3 SUMMARY TABLE
Position | Function | Factory Default | |
|
|
|
|
Input Impedance | On | } 200 Ohms | |
Input Impedance | Off | ||
Not yet assigned | n/a |
| |
|
|
|
|
Mode Selection | On | Point to Point | |
|
|
|
|
Local Loopback | Off | Disabled | |
|
|
|
|
Remote Loopback | Off | Disabled | |
|
|
|
|
Off | } Disabled | ||
Off |
|
Switches S3-1 & S3-2: Input Impedance
The setting for Switches
Setting | ||
On | On | 130 Ohms |
On | Off | 200 Ohms |
Off | On | 320 Ohms |
Off | Off | High impedance (minimum 2kΩ ) |
S3-1, S3-2 SELECTION TABLE FOR MODEL 1080A
Gauge of |
|
|
|
| Data Rates, kb/s |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
Cable | 1.2 | 1.8 | 2.4 | 3.6 | 4.8 | 7.2 | 9.6 | 14.4 | 19.2 | 28.8 | 38.4 | 57.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
19AWG/.9mm | 320 | 320 | 200 | 200 | 200 | 200 | 200 | 130 | 130 | 130 | 130 | 130 |
|
|
|
|
|
|
|
|
|
|
|
|
|
22AWG/.6mm | 320 | 320 | 320 | 200 | 200 | 200 | 200 | 200 | 130 | 130 | 130 | 130 |
|
|
|
|
|
|
|
|
|
|
|
|
|
24AWG/.5mm | 320 | 320 | 320 | 320 | 200 | 200 | 200 | 200 | 200 | 130 | 130 | 130 |
|
|
|
|
|
|
|
|
|
|
|
|
|
26AWG/.4mm | 320 | 320 | 320 | 320 | 320 | 200 | 200 | 200 | 200 | 200 | 130 | 130 |
S3-1, S3-2 SELECTION TABLE FOR MODEL 1080A-64
Gauge of | Data Rates, kb/s | |||
|
|
|
|
|
Cable | 16 | 32 | 64 | |
|
|
|
|
|
19AWG/.9mm | 130 | 130 | 130 | |
|
|
|
|
|
22AWG/.6mm | 200 | 130 | 130 | |
|
|
|
| |
24AWG/.5mm | 200 | 130 | 130 | |
|
|
|
|
|
26AWG/.4mm | 200 | 200 | 130 |
Switch S3-4: Mode Selection
The setting for switch
Setting | |
On | |
On | Multipoint application as “Master” |
Off | Multipoint application as “Slave” |
Switch S3-5: RS-232 Initiation of Local Loopback Test
The setting for switch
Setting | |
On | |
Off |