APPENDIX B
1090 CABLE RECOMMENDATIONS
The Patton Model 1090 operates at frequencies of 160 kHz or less and has been performance tested by Patton technicians using
Wire Gauge | Capacitance | Resistance |
19 AWG | 83nF/mi or 15.72 pF/ft. | .0163 Ohms/ft. |
22 AWG | 83nF/mi or 15.72 pF/ft. | .0326 Ohms/ft. |
24 AWG | 83nF/mi or 15.72 pF/ft. | .05165 Ohms/ft. |
26 AWG | 83nF/mi or 15.72 pF/ft. | .08347 Ohms/ft. |
To gain optimum performance from the Model 1090 Series, please keep the following guidelines in mind:
•Always use twisted pair wire—this is not an option.
•Use twisted pair wire with a capacitance of 20pF/ft or less.
•Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher AWG numbers than 26).
•Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainable. Functionality should not be affected.
•Many environmental factors can affect the maximum distances obtainable at a particular site. Use the data rate/distance table (below) as a general guideline only.
Model 1090 Distance Table in Miles
Wire Gauge
Data Rate | 19G | 22G | 24G | 26G |
(kbps) | ( 0.9 mm) | (0.64mm) | (0.5 mm) | (0.4 mm) |
160 | 8.14 | 5.87 | 4.07 | 3.03 |
144 | 8.52 | 6.06 | 4.36 | 3.13 |
128 | 9.00 | 6.16 | 4.64 | 3.22 |
112 | 9.19 | 6.25 | 4.83 | 3.22 |
80 | 9.19 | 6.44 | 5.21 | 3.22 |
72 | 10.80 | 6.63 | 5.49 | 3.41 |
64 | 10.98 | 6.82 | 5.49 | 3.41 |
56 | 11.08 | 6.82 | 5.49 | 3.41 |
48 | 10.80 | 6.63 | 5.40 | 3.31 |
|
|
|
|
|
APPENDIX C
1090 FACTORY REPLACEMENT PARTS
AND ACCESSORIES
Patton Model # | Description |
0805US | American Power Cord |
0805EUR | European Power Cord CEE 7 |
0805UK | United Kingdom Power Cord |
0805AUS | Australia/New Zealand Power Cord |
0805DEN | Denmark Power Cord |
0805FR | France/Belgium Power Cord |
0805IN | India Power Cord |
0805IS | Israel Power Cord |
0805JAP | Japan Power Cord |
0805SW | Switzerland Power Cord |
07M1090SVC | Service Manual |
19 | 20 |